問題

  • ノード1がノード2をテイクオーバー
  • ノード2のサービスプロセッサに接続できないため、ping SP IPはタイムアウトします。
  • A300にPSUが2台表示されて  MULTIFAULTいますが、ノード1はアクティブです。

::> run -node * environment status
2 entries were acted on.

Node: node1
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
PSU2                                   MULTIFAULT
PSU1                                   MULTIFAULT

EMS log:

[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Temperature is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Current is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan1 Speed is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan2 Speed is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Temp is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Volt is Unreadable
[?] Sun Apr 30 09:56:55 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Over Curr is Unreadable
[?] Sun Apr 30 09:57:30 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Crest Factor is Unreadable
[?] Sun Apr 30 09:57:30 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Crest Factor is Unreadable

 

[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 InPower Monitor is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 InPower Monitor is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Current is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Fault is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan2 Speed is Unreadable
[?] Sun Apr 30 09:57:44 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
[?] Sun Apr 30 09:57:45 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Temp is Unreadable
[?] Sun Apr 30 09:57:45 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Volt is Unreadable
[?] Sun Apr 30 09:57:45 +0800 [Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Curr is Unreadable

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.