メインコンテンツまでスキップ

CONTAP-221384:スイッチのISLを取り外したあとにSNMPアラートが送信されない。

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

問題

After unplugging the ISL, the following alert is generated in ONTAP, but no SNMP alert is sent out:

FR11BST1::> event log show Time Node Severity Event

------------------- ---------------- ------------- ---------------------------

2/28/2024 06:48:03 FR11BST1-1 ALERT hm.alert.raised: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = FR1-1B11-S-9336-01(FLM264202JJ)/Ethernet1/15 raised by monitor ethernet-switch

Once it's reconnected, an hm.alert.cleared is received in ONTAP, and a SNMP alert is sent out. The following error is seen in the notifyd logs:

Tue Mar 12 2024 08:07:15 +00:00 [kern_notifyd:info:2372] 0x80a47a200: 0: ERR: EMS::SNMP_HANDLER: Unable to send the event to mgwd. Reason: The event size is greater than the allowed maximum buffer size which is 2016

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.