ONTAP-70943:ボリュームが属するSVMに数字のみで構成される効率化ポリシーが設定されていると、ONTAPシステムマネージャでボリュームを編集できない
問題
- Edit Volume screen in System Manager shows error and pressing the Save button scrolls to the top:
"The server might not have processed the request. It cannot be determined if the operation was completed. Try again."
- Edit Volume screen in System Manager shows no error but pressing the Save button does not respond.
- sysmgr.log repots errors:
[Error stack]"TypeError: e.toLowerCase is not a function\n at t.getPolicyDisplay (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14419171)\n at t.getPolicyGenericObject (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14418958)\n at https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14445955\n at Array.forEach (<anonymous>)\n at t.handleEfficiency (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14445874)\n at t.handlePatchOptionData (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14417218)\n at t._next (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:14416366)\n at t.__tryOrUnsub (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:7099350)\n at t.next (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:7098495)\n at t._next (https://<cluster-mgmt-ip>/sysmgr/v4/main.e8596ba14ac74abffdf0.js:1:7097571)"