問題

After SVM-DR migration cutover, the CIFS shares may not be accessible The SVM is unable to connect to name services (DNS, Active Directory, LDAP) Example: 

::*> vserver services access-check authentication show-creds -node <node-name> -vserver <svm-name> -uid <uid> Vserver: <svm-name> (internal ID: <id>)

Error: Get user credentials procedure failed .. unreachable [ 9] Failed to connect to 10.10.10.100 for DNS: Network is unreachable ** [ 9] FAILURE: Unable to contact DNS to discover domain ** controllers. [ 9] Unable to make a connection (LDAP (NIS & Name Mapping):), Result: RESULT_ERROR_DNS_CANT_REACH_SERVER DNS is required to discover the AD domain services. dns check returns Network is unreachable Example:

::*> dns check -vserver svm1 -name-server x.x.x.x

Vserver: svm1 Name Server: x.x.x.x Name Server Status: down Status Details: Network is unreachable. The service-policy applied to the SVM's LIF does not have the necessary management client services added Example:

nas-cm911::> network interface show -vserver svm1 -lif lif1 -fields services vserver lif services ------- ---------- --------------------------------------------------- svm1 lif1 data-core,data-nfs,data-cifs

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.