メインコンテンツへスキップ

ANDU:検証フェーズで空の警告が表示される

Views:
174
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

環境

  • ONTAP 9
  • ANDU

問題

ONTAPのアップグレード時に検証フェーズ後に一部の警告が空になる:

  • CLI

cluster::*> cluster image show-update-progress

                       Estimated      Elapsed
Update Phase      Status           Duration     Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks   completed         00:10:00     00:00:40

Details:

Pre-update Check    Status       Error-Action
-------------------- ----------------- --------------------------------------
Aggregate online    OK         N/A
status and parity
check
Aggregate plex     OK         N/A
resync status check
Application      OK         N/A
Provisioning Cleanup
Broadcast Domain    OK         N/A
availability and
uniqueness for HA
pair status
CIFS compatibility   Warning       Warning: CIFS is currently in use.
status check               Any unprotected sessions may be
                    affected with possible loss of data.
                    Action: Stop all unprotected CIFS
                    workloads before performing the
                    update.To list the unprotected CIFS
                    workloads, run the command: vserver
                    cifs session show
                    -continuously-available No, Partial
CLAM quorum online   OK         N/A
status check
Capacity licenses   OK         N/A
install status check
Cloud keymanager    OK         N/A
connectivity check
Cluster health and   OK         N/A
eligibility status
Cluster quorum     OK         N/A
status check
Cluster/management   OK         N/A
switch check
Current system     OK         N/A
version check if it
is susceptible to
possible outage
during NDU
Data aggregates HA   OK         N/A
policy check
Disk status check   OK         N/A
for failed, broken
or non-compatibility
Encryption key     OK         N/A
migration status
check
External        OK         N/A
key-manager with
legacy KMIP client
check
External keymanager  OK         N/A
key server status
check
High Availability   OK         N/A
configuration
status check
Infinite Volume    OK         N/A
availibility check
LIF failover      OK         N/A
capability status
check
LIF health check    OK         N/A
LIF load balancing   OK         N/A
status check
LIFs is on home    OK         N/A
node status
Manual checks that   Warning       Warning: Manual validation checks
can be done using            need to be performed. Refer to the
Upgrade ONTAP              Upgrade Advisor Plan or the "What
documentation              should I verify before I upgrade with
                    or without Upgrade Advisor" section
                    in the "Upgrade ONTAP" documentation
                    for the remaining validation checks
                    that need to be performed before
                    update. Failing to do so can result
                    in an update failure or an I/O
                    disruption.
                    Action: Refer to the Upgrade Advisor
                    Plan or the "What should I verify
                    before I upgrade with or without
                    Upgrade Advisor" section in the
                    "Upgrade ONTAP" documentation for the
                    remaining validation checks that need
                    to be performed before update.
MetroCluster      OK         N/A
configuration
status check for
compatibility
Minimum number of   OK         N/A
aggregate disks
check
NDMP sessions check  OK         N/A
NFS mounts status   Warning       Warning: This cluster is serving NFS
check                  clients. If NFS soft mounts are used,
                    there is a possibility of frequent
                    NFS timeouts and race conditions that
                    can lead to data corruption during
                    the upgrade.
                    Action: Use NFS hard mounts, if
                    possible. To list Vservers running
                    NFS, run the following command:
                    vserver nfs show
NVMe over Fabrics   OK         N/A
license check
Name Service      Warning       Warning: None of the configured DNS
Configuration DNS            servers are reachable for the
Check                  following Vservers: SVMxxxx. There
                    might be other Vservers for which DNS
                    servers are not reachable.
                    Action: Delete the DNS server, or
                    verify that the DNS status is "up".
                    To verify the status, use the
                    "vserver services name-service dns
                    check" command. Delete the DNS
                    configuration for the Vservers which
                    do not have "dns" listed as a
                    configured source in the output of
                    the "vserver services name-service
                    ns-switch show" command.
Name Service    Warning     Warning:
Configuration LDAP
Check
Node to SP/BMC     OK         N/A
connectivity check
OKM/KMIP enabled    OK         N/A
systems - Missing
keys check
ONTAP API to REST   Warning       Warning: NetApp ONTAP API has been
transition warning            used on this cluster for ONTAP data
                    storage management within the last 30
                    days. NetApp ONTAP API is approaching
                    end of availability.
                    Action: Transition your automation
                    tools from ONTAP API to ONTAP REST
                    API. For more details, refer to
                    CPC-00410 - End of availability:
                    ONTAPI
                    https://mysupport.netapp.com/info/
                    communications/ECMLP2880232.html
ONTAP Image      Warning      Warning:
Capability Status
OpenSSL 3.0.x     OK         N/A
upgrade validation
check
Openssh 7.2 upgrade  OK         N/A
validation check
Pre-Update     Warning      Warning:
Configuration
Verification
Replicated database  OK         N/A
schema consistency
check
Running Jobs Status Warning      Warning:
SAN LIF association  OK         N/A
status check
SAN compatibility   Warning       Warning: Since this cluster is
for manual                configured for SAN, manually confirm
configurability             that the SAN configuration is fully
check                  supported.
                    Action: Refer to the NetApp
                    Interoperability Matrix Tool for
                    interoperability information.
SAN kernel agent    OK         N/A
status check
Secure Purge    Warning      Warning:
operation Check
Shelves and Sensors  OK         N/A
check
SnapLock Version  Warning      Warning:
Check
SnapMirror       OK         N/A
Synchronous
relationship status
check
SnapMirror       OK         N/A
compatibility
status check
Supported platform   OK         N/A
check
Target ONTAP      OK         N/A
release support for
FiberBridge 6500N
check
Upgrade Version   Warning     Warning:
Compatibility Status
Verify if a cluster  OK         N/A
management LIF
exists
Volume Conversion  Warning     Warning:
In Progress Check
Volume move      OK         N/A
progress status
check
Volume online     OK         N/A
status check
iSCSI target portal  OK         N/A
groups status check
Overall Status   Warning     Warning
57 entries were displayed.

  • System Manager

ym_sm_upgrade_warning1.png

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.