ANDU:検証フェーズで空の警告が表示される
環境
- ONTAP 9
- ANDU
問題
ONTAPのアップグレード時に検証フェーズ後に一部の警告が空になる:
- CLI
cluster::*> cluster image show-update-progress
Estimated Elapsed
Update Phase Status Duration Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks completed 00:10:00 00:00:40
Details:
Pre-update Check Status Error-Action
-------------------- ----------------- --------------------------------------
Aggregate online OK N/A
status and parity
check
Aggregate plex OK N/A
resync status check
Application OK N/A
Provisioning Cleanup
Broadcast Domain OK N/A
availability and
uniqueness for HA
pair status
CIFS compatibility Warning Warning: CIFS is currently in use.
status check Any unprotected sessions may be
affected with possible loss of data.
Action: Stop all unprotected CIFS
workloads before performing the
update.To list the unprotected CIFS
workloads, run the command: vserver
cifs session show
-continuously-available No, Partial
CLAM quorum online OK N/A
status check
Capacity licenses OK N/A
install status check
Cloud keymanager OK N/A
connectivity check
Cluster health and OK N/A
eligibility status
Cluster quorum OK N/A
status check
Cluster/management OK N/A
switch check
Current system OK N/A
version check if it
is susceptible to
possible outage
during NDU
Data aggregates HA OK N/A
policy check
Disk status check OK N/A
for failed, broken
or non-compatibility
Encryption key OK N/A
migration status
check
External OK N/A
key-manager with
legacy KMIP client
check
External keymanager OK N/A
key server status
check
High Availability OK N/A
configuration
status check
Infinite Volume OK N/A
availibility check
LIF failover OK N/A
capability status
check
LIF health check OK N/A
LIF load balancing OK N/A
status check
LIFs is on home OK N/A
node status
Manual checks that Warning Warning: Manual validation checks
can be done using need to be performed. Refer to the
Upgrade ONTAP Upgrade Advisor Plan or the "What
documentation should I verify before I upgrade with
or without Upgrade Advisor" section
in the "Upgrade ONTAP" documentation
for the remaining validation checks
that need to be performed before
update. Failing to do so can result
in an update failure or an I/O
disruption.
Action: Refer to the Upgrade Advisor
Plan or the "What should I verify
before I upgrade with or without
Upgrade Advisor" section in the
"Upgrade ONTAP" documentation for the
remaining validation checks that need
to be performed before update.
MetroCluster OK N/A
configuration
status check for
compatibility
Minimum number of OK N/A
aggregate disks
check
NDMP sessions check OK N/A
NFS mounts status Warning Warning: This cluster is serving NFS
check clients. If NFS soft mounts are used,
there is a possibility of frequent
NFS timeouts and race conditions that
can lead to data corruption during
the upgrade.
Action: Use NFS hard mounts, if
possible. To list Vservers running
NFS, run the following command:
vserver nfs show
NVMe over Fabrics OK N/A
license check
Name Service Warning Warning: None of the configured DNS
Configuration DNS servers are reachable for the
Check following Vservers: SVMxxxx. There
might be other Vservers for which DNS
servers are not reachable.
Action: Delete the DNS server, or
verify that the DNS status is "up".
To verify the status, use the
"vserver services name-service dns
check" command. Delete the DNS
configuration for the Vservers which
do not have "dns" listed as a
configured source in the output of
the "vserver services name-service
ns-switch show" command.
Name Service Warning Warning:
Configuration LDAP
Check
Node to SP/BMC OK N/A
connectivity check
OKM/KMIP enabled OK N/A
systems - Missing
keys check
ONTAP API to REST Warning Warning: NetApp ONTAP API has been
transition warning used on this cluster for ONTAP data
storage management within the last 30
days. NetApp ONTAP API is approaching
end of availability.
Action: Transition your automation
tools from ONTAP API to ONTAP REST
API. For more details, refer to
CPC-00410 - End of availability:
ONTAPI
https://mysupport.netapp.com/info/
communications/ECMLP2880232.html
ONTAP Image Warning Warning:
Capability Status
OpenSSL 3.0.x OK N/A
upgrade validation
check
Openssh 7.2 upgrade OK N/A
validation check
Pre-Update Warning Warning:
Configuration
Verification
Replicated database OK N/A
schema consistency
check
Running Jobs Status Warning Warning:
SAN LIF association OK N/A
status check
SAN compatibility Warning Warning: Since this cluster is
for manual configured for SAN, manually confirm
configurability that the SAN configuration is fully
check supported.
Action: Refer to the NetApp
Interoperability Matrix Tool for
interoperability information.
SAN kernel agent OK N/A
status check
Secure Purge Warning Warning:
operation Check
Shelves and Sensors OK N/A
check
SnapLock Version Warning Warning:
Check
SnapMirror OK N/A
Synchronous
relationship status
check
SnapMirror OK N/A
compatibility
status check
Supported platform OK N/A
check
Target ONTAP OK N/A
release support for
FiberBridge 6500N
check
Upgrade Version Warning Warning:
Compatibility Status
Verify if a cluster OK N/A
management LIF
exists
Volume Conversion Warning Warning:
In Progress Check
Volume move OK N/A
progress status
check
Volume online OK N/A
status check
iSCSI target portal OK N/A
groups status check
Overall Status Warning Warning
57 entries were displayed.
- System Manager