環境

  • ONTAP 9
  • FAS
  • クラスタネットワークスイッチ

問題

  • のクラスタポートのCRCエラー ifconfig:

-- interface  e0b  (232 days, 2 hours, 21 minutes, 3 seconds) --

RECEIVE
Total frames:    252m | Frames/second:    13  | Total bytes:    39644m
Bytes/second:    1977  | Total errors:    1218  | Errors/minute:     0
Total discards:    0  | Discards/minute:    0  | Multi/broadcast:  1020k
Non-primary u/c:    0  |CRCerrors:     1212| Runt frames:      0
Fragment:       0  | Long frames:      0  | Jabber:        3
Length errors:     3  | No buffer:       0  | Xon:          0
Xoff:         0  | Pause:         0  | Jumbo:       1293k
Noproto:        0  | Error symbol:    236  | Illegal symbol:   199
Bus overruns:     0  | Queue drops:      0  | LRO segments:    249m
LRO bytes:     26713m
| LRO6 segments:     0  | LRO6 bytes:      0
Bad UDP cksum:     0  | Bad UDP6 cksum:    0  | Bad TCP cksum:     0
Bad TCP6 cksum:    0  | Mcast v6 solicit:   0
TRANSMIT
Total frames:    561m | Frames/second:    28  | Total bytes: 139g
Bytes/second:    6980  | Total errors:     0  | Errors/minute:     0
Total discards:    0  | Queue overflow:    0  | Multi/broadcast:  1031k
Xon:          0  | Xoff:         0  | Pause:         0
Jumbo:       2565k | Cfg Up to Downs:    2  | TSO non-TCP drop:   0
Split hdr drop:    0  | Timeout:        0  | TSO segments:    402k
TSO bytes:     4840m | TSO6 segments:     0  | TSO6 bytes:      0
HW UDP cksums:    154k | HW UDP6 cksums:    0  | HW TCP cksums:    556m
HW TCP6 cksums:    0  | Mcast v6 solicit:   0
DEVICE
Mcast addresses:    3  | Rx MBuf Sz:     4096
LINK INFO
Speed:       10000M | Duplex:       full | Flowcontrol:     none
Media state:    activ
e | Up to downs: 8

 

  • EMSエラー:

Tue Dec 01 04:04:26 JST [Cluster-01: intr: netif.linkErrors:error]: Excessive link errors on network interface e0b. Might indicate a bad cable, switch port, or NIC, or that a cable connector is not fully inserted in a socket. On a 10/100 port, might indicate a duplex mismatch.

Sun Jan 22 00:27:18 +0100 [Cluster-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif Cluster_clus2 (node ​​Node02) to cluster lif Cluster-01_clus1 ( node Node01).

 
 

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.