問題
::*> cluster image show-update-progress
Update Phase Status Estimated Duration Elapsed Duration-------------------------------------------------------------------Pre-update checks completed 00:02:00 00:01:18
Details:Pre-update Check Status Error-Action--------------------------------------------------------------CPU Utilization Warning Warning: CPU utilization is high on nodes: NODE1. Action: Before updating a node, verify that no node in the cluster is above 50% CPU utilization. Use the command "node run -node <nodenames> -command sysstat -c 103" to view the CPU utilization of nodes.SAN compatibility check Warning Warning: This cluster is configured for SAN or NVMe protocol access. Confirm that the configuration is fully supported. Action: Refer to the NetApp Interoperability Matrix Tool for interoperability information.