FCPコマンドの失敗が原因でストレージでリンクが継続的に切断される
環境
- ONTAP 9.X
- FCP
問題
- NetAppストレージポートがファブリックにログインしようとすると、すべてのコマンドが失敗として表示される
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 2a with event status 1 , topology type 1, status1 0x0, status2 0x0.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_IO_FC_CT, command GPL, subtype x1, with status of 3 and an extended status x4 for NPIV port 0.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_IO_FC_CT, command RSPN_ID, subtype x2, with status of 3 and an extended status x4 for NPIV port 0.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_ELS_REQ, command FLOGI, subtype x0, with status of 3 and an extended status x4 for NPIV port 0.
[netapp-01: fct_tpd_work_thread_0: scsitarget.fct.loginfailed:error]: FC port 2a, NPIV port 0 failed fabric login with status of 3 and an extended status of x4.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_ELS_REQ, command FDISC, subtype x0, with status of 3 and an extended status x4 for NPIV port 2.
[netapp-01: fct_tpd_work_thread_0: scsitarget.fct.loginfailed:error]: FC port 2a, NPIV port 2 failed fabric login with status of 3 and an extended status of x4.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_ELS_REQ, command FDISC, subtype x0, with status of 3 and an extended status x4 for NPIV port 1.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_IO_FC_CT, command RSPN_ID, subtype x2, with status of 3 and an extended status x4 for NPIV port 2.
[netapp-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 2a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x4 for NPIV port 0.
Invalid transmission word
SFPを搭載した問題を示すストレージに記録中- スイッチ側SFPは すでに交換済み( 問題は続き)