False MissingPathFromSwitchToNSM_Alertを断続的に受信
環境
- NS224
- スイッチ化ストレージ
- ONTAP 9.13.1PX
問題
- 複数のシェルフから断続的に「MissingPathFromSwitchToNSM_Alert」を受信しています:
Sat Jan 27 17:35:11 -0600 [Netapp01-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: MissingPathFromSwitchToNSM_Alert[14.1:A].
Sun Jan 28 18:15:21 -0600 [Netapp01-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: MissingPathFromSwitchToNSM_Alert[16.4:B].
Sun Jan 28 20:05:22 -0600 [Netapp01-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: MissingPathFromSwitchToNSM_Alert[14.5:B].
Wed Jan 31 21:40:55 -0600 [Netapp01-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: MissingPathFromSwitchToNSM_Alert[12.1:B].
- アラートはただちにクリアされ、永続的ではありません。
Wed Jan 31 21:39:50 -0600 [Netapp01-01: schmd: hm.alert.raised:alert]: Alert Id = MissingPathFromSwitchToNSM_Alert , Alerting Resource = 12.1:B raised by monitor system-connect
Wed Jan 31 22:17:30 -0600 [Netapp01-01: schmd: hm.alert.cleared:notice]: Alert Id = MissingPathFromSwitchToNSM_Alert , Alerting Resource = 12.1:B cleared by monitor system-connect
- 次のアラートの期間中は、ノードがクアッドパスHAから移行することはありません。
System Storage Configuration: Multi-Path HA
- アラートの期間中、シェルフエラーに関連する他のインジケータはイベントログに表示されません。
- 診断シェルフのログを確認しても、アラートやエラーは報告されません。
- ONTAP側のケーブル接続と構成を確認します。すべてが正しくケーブル接続されており、ノードが正しいケーブル 接続を報告していることを確認します。Cable shelves as switch-attached storage - NS224 shelves