メインコンテンツへスキップ

ボリュームの制限が原因でノードが部分的なギブバックで停止する

Views:
20
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

環境

  • ONTAP 9
  • AFF / FAS

問題

  • 出力storage failover show-giveback -instanceエラーを報告します:
Aggregates Giveback State: Failed: destination cannot receive the aggregate.
Check failed by wafl. Check the event log
 
Aggregates Giveback State: No aggregates to give back
aggr.relocation.failed: Relocation of aggregate aggr01 failed by node node01 because destination check failed
  • チェック中event log show -message-name *giveback*追加情報が得られます:

[cluster-N2: statd: raid.fm.leftBehindAggr:notice]: Aggregate aggr1_N1 was left behind during giveback.
[cluster-N2: cf_giveback: wafl.arl.vol.limitChkFailed:error]: Aggregate 'aggr1_N1': Volume limits check failed on destination node Volume count (1102) exceeds system limit (1000)..
[cluster-N2: cf_giveback: sfo.sendhome.subsystemAbort:alert]: The giveback operation of 'aggr1_N1' was aborted by 'wafl'.
[cluster-N2: cf_giveback: sfo.giveback.failed:alert]: Giveback of aggregate aggr1_N1 failed due to destination check failed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.