メインコンテンツまでスキップ

データサーバでの「volume efficiency」コマンドが原因で9.14.1PxへのONTAPアップグレードが一時停止しました

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

環境

  • ONTAP 9.14.1Pxへのアップグレード
  • MetroCluster 

問題

  • スイッチオーバーが拒否されたため、MetroClusterでのONTAPのアップグレードが一時停止されました:
::> cluster image show-update-progress
                   Estimated     Elapsed
Cluster                Duration     Duration Status
------------------------------ --------------- --------------- ----------------
cluster01               XX:XX:XX    XX:XX:XX  completed
cluster02               XX:XX:XX    XX:XX:XX paused-on-error
Details: Switchover paused.
 
  • metrocluster operation show スイッチオーバー試行の失敗を報告します。 

[Job XXXX] Job failed: Failed to validate the node and cluster components before the switchover operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the comman again.

  • metroclsuter vserver show デグレード状態のデータSVMをレポートします: 
::> metrocluster vserver show
Cluster: cluster02
Partner            Configuration
Vserver           Vserver            State
-------------------     ----------------------     -----------------svm01            svm01-mc          degraded
Corrective Action: Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
  • 影響を受けるSVM  には、セキュリティアクセス制御ロールのvolume efficiency entresがあります。 

::> security login role show -vserver * -role * -cmddirname "volume efficiency"*

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.