メインコンテンツまでスキップ

接頭辞「UNC」を持つファイル名またはフォルダ名がソースに存在すると、XCP同期タスクが停止する

Views:
4
Visibility:
Public
Votes:
0
Category:
netapp-xcp<a>2009779036</a>
Specialty:
nas
Last Updated:

環境

XCP SMB

問題

  • XCP同期タスクが進捗せずに長時間停止する
  • XCPログにXCP.synchronizerエラーが表示される。
  • エラー:
2023-10-12 09:19:03,932 - ERROR - xcp.synchronizer - failed to copy "ntap\abc\test\test": (1, 'ReadFile', 'Incorrect function.')
2023-10-12 09:19:06,696 - ERROR - xcp.synchronizer - failed to remove from target "ntap\abc\test\test": [Errno 13] The process cannot access the file because it is being used by another process:
2023-10-12 09:19:50,352 - WARNING - xcp.fs - error setting timestamps on "ntap\abc\test\test": errno (code: 32) The process cannot access the file because it is being used by another process.
  • フォルダは、保存先のXCPによってファイルとして作成されます。
  • パケットトレースは、SMB作成呼び出しによる、ファイルおよびFilerの下にフォルダを作成するループを示しています。STATUS_OBJECT_PATH_NOT_FOUND(0xc000003a)
No    Time       Source  Destination Proto Info
306154  11:22:29.509384 10.x.x.x 10.x.x.x   SMB2  Create Request File: ntap\abc\test\test\ts01
306155  11:22:29.509474 10.x.x.x 10.x.x.x   SMB2  Create Response, Error: STATUS_OBJECT_PATH_NOT_FOUND

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.