環境

  • ONTAP 9
  • Cisco MDS
  • テープ・ドライブ

問題

  • Ciscoスイッチを介してテープストレージに接続されているFCイニシエータポートがオフラインになっている( SYSCONFIG-A またはを参照) FC-INIT-PORT-INFO.XML
slot 0: FC Host Adapter 0c (QLogic 8324 rev. 2, N-port, <OFFLINE (hard)>)
  • EMSに表示されるリンク切断:
Tue Feb 13 22:55:20 +0100 [node1: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 0c.
Tue Feb 13 22:55:50 +0100 [node1: isp2400_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 0c after 30 seconds. Taking the adapter offline.
  • ケーブルを抜き差しするか交換すると、アダプタが数秒間オンラインになり、その後再びオフラインになります。
Mon Feb 19 09:09:39 +0100 [node1: isp2400_asyncd_0: fci.adapter.online:info]: Fibre Channel adapter 0c is now online.
Mon Feb 19 09:11:46 +0100 [node1: isp2400_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 0c.
Mon Feb 19 09:12:17 +0100 [node1: isp2400_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 0c after 30 seconds. Taking the adapter offline.
  • ノードから失われたテープドライブ:

Mon Feb 19 09:12:17 +0100 [node1: isp2400_asyncd_0: mlm.tapemc.lun.removed:notice]: The tape LUN 'XXXXXXXXXXX:XXXXXXXXX' (S/N: XXXXXXXXXX) is no longer visible to this node.

  • スイッチは良好なTX電力を報告しますが、低いRX電力を報告します。
`show interface`
[...]
fc1/11 is down (Link failure or not-connected)
[...]
Temperature 32.90 C, Voltage 3.28 V, Current 7.10 mA, TxPower -0.27 dBm, RxPower -40.00 dBm --
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.