メインコンテンツまでスキップ

SANリンクアラートを作成する方法

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

環境

ONTAP

説明

イベントカタログを使用して、SANターゲットイベント通知を設定し、カスタムアラートを使用してEメールアドレスに送信する方法:

event catalog show -message-name scsitarget.fct.reset

     Message Name: scsitarget.fct.reset
         Severity: NOTICE
      Description: This message occurs when the FCT adapter is being reset.
Corrective Action: UNKNOWN
   SNMP Trap Type: Severity-based
    Is Deprecated: false

     Message Name: scsitarget.fct.linkError
         Severity: ERROR
      Description: This message occurs when a Fibre Channel (FC) Host Bus Adapter (HBA) encounters a physical layer issue. This might result in the frame being dropped. The following are examples of protocol errors that result in this message: - Bad start of frame (SOF) - Bad end of frame (EOF) - CRC error - Running disparity error - Link Reset primitive detection
Corrective Action: Recurring instances of this message indicate a physical layer issue. Perform the following recovery actions: - Verify that the overall SAN fabric is healthy. - Verify that the SFP is healthy at both endpoints, replace if necessary. - Clean or replace the cables. Contact technical support with the code and status information for further analysis.
   SNMP Trap Type: Severity-based
    Is Deprecated: false

 
エラーの例:
fct_tpd_thread_3: scsitarget.fct.reset:notice]: Resetting Fibre Channel target adapter 1a
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.