環境

  • ONTAP 9
  • Brocade FCスイッチ

問題

  • 複数のノードのFCアダプタのEMSログにリンク切断が記録される:
Tue Feb 13 01:11:22 +0000 [node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 1c with event status 1 , topology type 1, status1 0x0, status2 0x0.
Tue Feb 13 01:11:23 +0000 [node2: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 1c with event status 1 , topology type 1, status1 0x0, status2 0x0.
  • SYSCONFIG-A のノードでは、該当するアダプタが同じスイッチに接続されています。たとえば、両方とも switch2次のように接続されます。
slot 1: Fibre Channel Target Host Adapter 1c
Switch Port:    switch2:68
 
slot 1: Fibre Channel Target Host Adapter 1c
Switch Port:    switch2:69
  • Brocadeスイッチでは errdump -aKernel Panic 、リンクが切断された時点でリブートが報告されています。
2024/02/13-01:32:26, [HAM-1004], 6610602, CHASSIS, INFO, BrocadeG630, Processor rebooted - Software Fault:Kernel Panic.
  • スイッチコアファイル の内容 Oops
Oops taken on: 2024-02-13 at 01:31:29:458270
Oops: Machine check, sig: 7 [#1]
  • errdumpall 表示内容:
2024/02/13-01:32:26:106787, [PLAT-8054], 6628542/0, CHASSIS, INFO, BrocadeG630, Enable PCIe event IRQs 1, syspcie.c, line: 879, comp:rc, ltime:2024/02/13-01:32:22:249888
2024/02/13-01:32:26:106816, [HAM-1004], 6628543/6610602, CHASSIS, INFO, BrocadeG630, Processor rebooted - Software Fault:Kernel Panic., reboot.c, line: 117, comp:hamd, ltime:2024/02/13-01:32:23:265990
2024/02/13-01:32:26:106835, [IPC-5023], 6628544/0, CHASSIS, WARNING, BrocadeG630, HAM_PEER:1745 attempts to send message type(24) to invalid dest(EMIPC:0/0), comm.c, line: 474, comp:hamd, ltime:2024/02/13-01:32:24:280505

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.