autosupportSendErrorのSNMPトラップがHTTPエラー503で連続して通知される
環境
ONTAP 9
問題
- 次のSNMPトラップが継続的に通知されました
#XX autosupportSendError<DC=[XXX] HOST=[XXX]IPADDRESS=[XXX] TAG_Resource=[XXX]xSLAkey=[autosupportSendError] TAG_Ifdesc=[]>
[ productTrapData.0 = ""AutoSupport message (HA Group Notification from XXX (OUT OF INODES) ERROR) was not sent.
The system will drop the message."" productSerialNum.0 = ""XXX"", [DC=XXX]]
NOTIFYD
ログはHTTPエラーコード 503を示します。
0000001a.0046a1b1 1dbaed49 Sat Jan 25 2025 00:25:06 +00:00 [kern_notifyd:info:1442] 0x80d4d1100: 0: ERR: AutoSupport::OnDemand: Unable to send trigger request to ASUP OnDemand Server
0000001a.0046a1b2 1dbaed49 Sat Jan 25 2025 00:25:06 +00:00 [kern_notifyd:info:1442] 0x80d4d1100: 0: ERR: AutoSupport::OnDemand: HTTP POST failed, code: 503
~
0000001a.0046a1bd 1dbaed49 Sat Jan 25 2025 00:25:06 +00:00 [kern_notifyd:info:1442] (category: 1442:5153:deliver) (emittime: 1/25/2025 00:22:29) (message: deliver_ http_asup: HTTP PUT response error, status code 22, chunk: 0 of 0)
~
0000001a.0046a25e 1dbaed7f Sat Jan 25 2025 00:25:12 +00:00 [kern_notifyd:info:1442] Retry http ASUP delivery: seq num= 5153, subj= HA Group Notification from XXX (OUT OF INODES) ERROR
(OUT OF INODES) ERROR
が短時間に送信するAutoSupportメッセージの数が多すぎます。Sun Dec 29, 2024 23:06:11 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 22:06:05 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 21:06:01 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 20:05:07 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 19:05:02 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 18:04:19 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 17:04:06 +0000 HA Group Notification (OUT OF INODES) ERROR
Sun Dec 29, 2024 16:03:26 +0000 HA Group Notification (OUT OF INODES) ERROR