お客様が
vol conversion start
""のコマンドを実行しても、次のエラーが発生して失敗しました。Cluster-01::*> run local vol options test
nosnap=off, nosnapdir=off, minra=off,
no_atime_update=off, nvfail=off,
ignore_inconsistent=off, snapmirrored=off,
create_ucode=on,convert_ucode=on,
maxdirsize=327680, schedsnapname=create_time,
fs_size_fixed=off, guarantee=none,
svo_enable=off, svo_checksum=off,
svo_allow_rman=off, svo_reject_errors=off,
no_i2p=off,fractional_reserve=0, extent=off,
try_first=volume_grow,sis_logging=off, read_realloc=off,
snapshot_clone_dependency=off,
dlog_hole_reserve=off, batched_free_log_cap=1.50%, space_slo=none,
zombie_reclamation_priority=auto, dir_holes=on,
logical_space_enforcement=off,
logical_space_reporting=off
Cluster-01::*> vol conversion start -vserver SVM-B -volume test
Warning: * After the volume is converted to a FlexGroup, it will not be possible to change it back to a flexible volume.
* Converting flexible volume "test" in Vserver "SVM-B" to a FlexGroup will cause the state of all Snapshot copies from the volume to be set to "pre-conversion". Pre-conversion Snapshot copies cannot be restored.
* Converting the volume to a FlexGroup will not add additionalresources for capacity. After converting, use the "volume expand" command to add resources.
Do you want to continue? {y|n}: y
[Job 685] Renaming volume back to original name.
Error: command failed: [Job 685] Job failed: Volume conversion failed. Reason:
Volume with DSID 1055 cannot be converted to a FlexGroup volume because its configuration is not supported by FlexGroup volumes. Contact technical support for further assistance.