メインコンテンツまでスキップ

ファンアウトを使用して ID 保持の SVM-DR を新しいクラスタに移行できますか。

Views:
147
Visibility:
Public
Votes:
0
Category:
snapmirror
Specialty:
dp
Last Updated:

環境

  • ONTAP 9.3 以前
  • SVM-DR
  • SnapMirror

回答

ONTAP 9.3 以前の回避策:

  1. Volume SnapMirror を使用して、新しいクラスタの SVM にデータを移行します
  2. 元の SVM-DR を解除してからリリースします
  3. 新しい Volume SnapMirror を SVM-DR に変換します

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.