SVM-DRの更新または再同期で効率化設定を変更できませんでした
環境
- ONTAP 9
- SnapMirror
- SVM-DR
- Storage Efficiency
- SVM-DR再同期
問題
SVM-DR関係のSnapMirror更新または再同期が失敗します
Failed to apply the source Vserver configuration.
Reason: Failed to modify efficiency configuration for volume "<volume>" of Vserver "<SVM>": Compression cannot be disabled when inline compression or incompressible data detection is enabled on the volume. Disable inline compression and retry the command. If there are active SIS operations then use the "volume efficiency stop -all true -vserver * -volume *" command to stop all efficiency operations on all volumes in the cluster. Failed to apply the source Vserver configuration.
Failed to apply the source Vserver configuration.
Reason: Apply failed for Object: sis Method: baseline. Reason: Failed to modify efficiency configuration for volume "Dst_Vol" of Vserver "Dst_SVM": Cannot change the efficiency policy from "auto" because there is an active "auto" background efficiency operation on the volume. Use the "volume efficiency status" command to view the status of background efficiency operation on the volume. Use the "volume efficiency stop" command to issue stop on the running operation. If there is an active efficiency operation then use the "volume efficiency stop -all true -vserver "Dst_SVM" -volume "Dst_Vol" command to stop all efficiency operations on the volume "Dst_Vol".
Execute "snapmirror show -destination-vserver Dst_SVM -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.