環境

  • Data ONTAP 9.x
  • SnapMirror
  • SVM DR
  • NetApp SnapMirrorビジネス継続性(SMBC)

問題

  • さまざまなタイプのSnapMirror処理  (更新、 再同期、初期化、リストア)が失敗する可能性があり、高密度サブシステムを参照する可能性があります
  • SnapMirror の再同期 が次のエラーで失敗します。

[Cluster: sm_logger_main: smc.snapmir.resync.fail:error]: Resync from source volume 'SVM1:VOL1' to destination volume 'SVM2:VOL2' failed with error 'Failed to start transfer for Snapshot copy "snapmirror.UUID_SN.Year-MM-DD_TIME".(Failed to start transfer.(Replication operation failed because of error in dense subsystem))'. Relationship UUID 'UUID'.

Tue Sep 26 01:30:34 EDT 2017 ScheduledUpdate[Sep 26 01:12:00]:25335912-a00c-11e7-bfd1-00a098b44571 Operation-Uuid=bbb93bef-42df-4b05-8974-3993aa7ed614 Group=none Operation-Cookie=0 action=Defer source=src_svm:src_vol destination=dr_svm:dr_vol status=Failure message=Failed to start transfer for Snapshot copy "hourly.2017-09-26_0010".(Failed to start transfer.(Replication operation failed because of error in dense subsystem))

  • または、次のようなエラーが表示されます。

Failed to enable efficiency on volume "VOLUME" of Vserver "VSERVER": Operation is not configured.
Transfer

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.