SVMがVVolアプリケーションをホストしているとSVMの移行が失敗する
環境
- ONTAP 9
- SVMの移行
- SVMのデータ移動
- AppDM(アプリケーション対応データ管理)
問題
- VVolのアプリケーション対応データ管理(Appdm)をホストするSVMを移行しようとすると、移行が失敗します。
DstCluster::> vserver migrate show
Destination Source
Vserver Cluster Cluster Status
---------------- ------------------- ------------------- ---------------------
SrcVserver DstCluster SrcCluster Migrate-failed
Status Details: Migrate operation failed. Reason: Application of configuration failed for Vserver "SrcVserver". Reason: Failed
when polling for the migrate operation completion for Vserver "SrcVserver". Reason: Apply failed for Object: appdmObjectUI Method: baseline. Reason: Application "ISO" was not found in Vserver "SrcVserver". To resume the Vserver migrate operation, use the "vserver
migrate resume" command. To change the source Vserver configuration, use the "vserver migrate pause" command on the destination cluster, make the
configuration changes on the source cluster, and then use the "vserver migrate resume" command on the destination cluster.