メインコンテンツまでスキップ

ATTOブリッジが予期せずリブートし、ウォッチドッグタイマーが中断されました

Views:
3
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009578138</a>
Last Updated:

環境

  • ONTAP 9
  • ファブリック接続MetroCluster
  • ATTO 7500N Fibrebridgeの略
  • ATTOファームウェアが3.25より前です

問題

  • ATTO Birdgeが予期せずリブートし、AutoSupport で次の通知がトリガーされます。

System Notification (Bridge Unexpected Reboot: FB7500NX0XXXX) ALERT

  • イベントログには次のイベントが表示されます。
[Node-01: dsbridge_admin: bridge.removed:info]: FC-to-SAS bridge Broc-sw2:6.126L0 [ATTO    FibreBridge7500N 3.10] S/N [FB7500NXXXXXX] was removed.
[Node-01: dsbridge_admin: bridge.discovered:info]: FC-to-SAS bridge Broc-sw2:6.126L0 [ATTO    FibreBridge7500N 3.10] S/N [FB7500NXXXXXX] was discovered.
[Node-01: dsbridge_admin: bridge.rebooted:debug]: FC-to-SAS bridge Broc-sw2:6.126L0 [ATTO    FibreBridge7500N 3.10] S/N [FB7500NXXXXXX] was rebooted.
[Node-01: dsbridge_admin: callhome.bridge.reboot.unexp:alert]: Call home for Bridge Unexpected Reboot: FB7500NXXXXXX
  •  ATTOブリッジのイベントログには次の情報が表示されます。

0C6711 15:57:50 10/11/20 INFO ResConf:0E1E1FBD90 Dvc:5000c500b8ad904e Rsvd:0E1E1FBD91
0C6712 15:59:44 10/11/20 INFO ResConf:0E1E1FBD91 Dvc:5000c500b8ad9f12 Rsvd:0E1E1FBD90
0C6713 15:59:44 10/11/20 INFO ResConf:0E1E1FBD91 Dvc:5000c500b8ad9f12 Rsvd:0E1E1FBD90
0C6714 16:00:47 10/11/20 INFO ResConf:0E1E1FBA71 Dvc:5000c500b8ae3996 Rsvd:0E1E1FBA70
0C6715 16:01:58 10/11/20 WARN SWWD 3521
0C6716 16:01:58 10/11/20 INFO SWWD Exception
0C6717 16:01:58 10/11/20 INFO 10/11/2020 16:01:58
0C6718 16:01:58 10/11/20 INFO ST[006be480-006c0480] | FP[006c02d4] CPSR[60000192]
0C6719 16:01:58 10/11/20 INFO 001494b4<-001dccdc | SP[006c02d8] FP[006c0304]
0C671A 16:01:58 10/11/20 INFO 001dc9c4<-001955ec | SP[006c0308] FP[006c0324]
0C671B 16:01:58 10/11/20 INFO 0019531c<-00192598 | SP[006c0328] FP[006c0334]
0C671C 16:01:58 10/11/20 INFO 00192584<-0000189c | SP[006c0338] FP[006c03b0]
0C671D 16:01:58 10/11/20 INFO 0018b10c<-002762f8 | SP[006c03b4] FP[006c03e0]
0C671E 16:01:58 10/11/20 INFO 002761cc<-001dcc24 | SP[006c03e4] FP[006c0410]
0C671F 16:01:58 10/11/20 INFO 001dc9c4<-001955ec | SP[006c0414] FP[006c0430]
0C6720 16:01:58 10/11/20 INFO 0019531c<-00192598 | SP[006c0434] FP[006c0440]
0C6721 16:01:58 10/11/20 INFO 00192584<-0000189c | SP[006c0444] FP[00010001]
0C6722 16:01:58 10/11/20 INFO FP out of range [6c0440]
0C6723 16:01:58 10/11/20 INFO Duplicate CPSR
0C6724 16:01:58 10/11/20 INFO Exception occurred. Possible redundant preceding log entries
0C6725 00:00:05 01/01/00 INFO Reset.  HW Code: Software Warm
0C6726 00:00:05 01/01/00 INFO Reset.  Reason: Watchdog Timer Interrupt Exception
0C6727 16:04:01 10/11/20 SYS  System date has changed. Current date:[10/11/2020]
0C6728 16:04:01 10/11/20 INFO Boot/reset occurred (007A)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?