メインコンテンツまでスキップ

アグリゲートのプレックスは、両方のサイトのディスクで構成されます

Views:
8
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • ファブリック接続MetroCluster
  • ONTAP 9

問題

1 つ以上のプレックスは、別々の MetroCluster サイトに物理的に配置されたディスクで構成されます。

例:

Aggregate aggr1 (online, raid_dp, mirrored) (block checksums) Plex /aggr1/plex0 (online, normal, active, pool0) RAID group /aggr1/plex0/rg0 (normal, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity 0a.40.0 0a 40 0 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 parity 0a.40.1 0a 40 1 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.2 0a 40 2 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.3 0a 40 3 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.4 0a 40 4 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.5 0a 40 5 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.6 0a 40 6 SA:B 0 SSD N/A 3662580/7500964352 3662830/7501476528 Plex /aggr1/plex1 (online, normal, active, pool1) RAID group /aggr1/plex1/rg0 (normal, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity 0a.40.18 0a 40 18 SA:B 1 SSD N/A 3662580/7500964352 3662830/7501476528 parity 0b.60.0 0b 60 0 SA:A 1 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.19 0a 40 19 SA:B 1 SSD N/A 3662580/7500964352 3662830/7501476528 data 0b.60.1 0b 60 1 SA:A 1 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.20 0a 40 20 SA:B 1 SSD N/A 3662580/7500964352 3662830/7501476528 data 0b.60.2 0b 60 2 SA:A 1 SSD N/A 3662580/7500964352 3662830/7501476528 data 0a.40.21 0a 40 21 SA:B 1 SSD N/A 3662580/7500964352 3662830/7501476528

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.