「DomainMismatchFromNodeToShelf_Alert」がMetroCluster IPスイッチで報告されました
環境
- ONTAP 9
- MetroCluster IP
- NS224シェルフ - スイッチ接続
- Cisco 9336C-FX2
問題
MetroCluster IPスイッチで「DomainMismatchFromNodeToShelf_Alert」が報告されています:
Node ClusterA-02Monitor system-connectAlert IDDomainMismatchFromNodeToShelf_AlertAlerting Resource Switch-04Subsystem SAS-connect_ClusterIndication Time Fri Jul 25 08:52:47 2025Perceived Severity MajorProbable Cause Configuration_errorDescription The storage domain between the nodes ClusterA-01, ClusterA-02 and switch Switch-04 is different from the domain between the switch and shelves 4.40, 4.50, 4.60, 4.70.Corrective Actions Connect the switch Switch-04 to both the node and the shelves with the same storage domain, following the guide applicable to your shelf.Possible Effect This issue will affect conversions to direct-attached storage.Additional Information Switch Name: Switch-04Nodes: ClusterA-01, ClusterA-02Ports: ClusterA-01:e10a, ClusterA-02:e10aConnected Shelves: 4.40, 4.50, 4.60, 4.70Nodes Connected to Switch Port Range A: Switch-03, Switch-04Nodes Connected to Switch Port Range B:Alerting Resource Name Switch name: Switch-04- このアラートは、初期インストール時またはメンテナンス作業中に初めて発生しました。
- システムストレージ構成では、「クワッドパス」HAが報告されます。
- システムは現在、以下のように正しく配線されています: