メインコンテンツまでスキップ

MetroCluster IP SyncMirror プレックスに失敗しました

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • MetroCluster IP
  • ONTAP 9

問題

  • SYNCMIRROR PLEX FAILED MetroCluster IPのAutoSupport メッセージを受信しました:

[Node-02: config_thread: raid.rg.degraded:notice]: : Raid group /aggr1_02/plex2/rg0 is degraded
[Node-02: config_thread: raid.vol.mirror.degraded:alert]: Aggregate aggr1_02 is mirrored and one plex has failed. It is no longer protected by mirroring.
[Node-02: config_thread: callhome.syncm.plex:alert]: Call home for SYNCMIRROR PLEX FAILED

  • iSCSI接続を終了することが確認された場合、次のコマンドを使用して接続を終了します。

event log show -event *”iSCSI CAM target layer's session state is changed to terminated”*

  • ファブリック2のiSCSI接続を終了します。
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:3e6c6101-aab1-11ec-a3f8-d039ea3b9999 (address: 10.1.2.3). Reason: no ping reply after 5 seconds.
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:2f048313-aab1-11ec-8d08-d039ea3b1111 (address: 10.1.2.4). Reason: no ping reply after 5 seconds.
  • ファブリック1の接続が終了し、プール1のディスクが認識されなくなり、リモートプレックスに障害が発生します。
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:3e6c6101-aab1-11ec-a3f8-d039ea3b9999 (address: 10.1.1.3). Reason: no ping reply after 5 seconds.
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:2f048313-aab1-11ec-8d08-d039ea3b1111 (address: 10.1.1.4). Reason: no ping reply after 5 seconds.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.