メインコンテンツまでスキップ

MetroCluster のスイッチオーバーに失敗しました:次のクラスタはピア関係にありません

Views:
14
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • MetroCluster
  • クラスタ ピア
  • スイッチオーバー 

問題

  • スイッチオーバーのシミュレーションが失敗して次のエラーメッセージが表示されます

ClusterA::> set -privilege advanced

ClusterA::*> metrocluster switchover -simulate true
Job failed: Unable to set node and cluster components for switchover operation. Use the "metrocluster operation show" 
command to view detailed error information. Fix the errors, then retry the command.

  • MetroCluster チェックの結果、コンポーネントに警告が発生 clustersしました。

ClusterA::> metrocluster check show

Last Checked On: 1/26/2023 12:09:29

Component       Result
------------------- ---------
nodes         ok
lifs         ok
config-replication  ok
aggregates      ok
clusters       warning
connections      ok
volumes        ok
7 entries were displayed.

ClusterA::> metrocluster check cluster show -instance

             Type of Check: negotiated-switchover-ready
             Cluster Name: ClusterA
          Result of the Check: warning
Additional Information/Recovery Steps: Check system components in cluster ClusterA for negotiated-switchover: [Job 782] Job failed: Failed to set up the node and cluster components for the switchover operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command again.

  • MetroCluster 処理では次の情報が表示されます。

ClusterA::> metrocluster operation show
    Operation: switchover-simulate
      Status: failed
      Errors: Failed to configure the node and cluster components for the switchover operation.
          ClusterB (fatal): The following clusters are not peered with this cluster: ClusterZ. Create a peering 
          relationship with these clusters, verify that the peer cluster is available using the "cluster peer                   show", then retry the command.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.