環境

  • AFF-A700
  • ヘッド-スワップ
  • ONTAP 9
  • DR設定のレプリケーション 

問題

  • metrocluster config-replication resync-status シッパイシタバアイ

Cluster1::*> metrocluster config-replication resync-status show

Source                  Destination             State       % Complete
----------------------- ----------------------- ----------- ----------
Cluster1           Cluster2              complete        -
Cluster2      Cluster1                   failed          -

  • metrocluster vserver show の出力で、 1つ以上のSVMにライセンスがないことに関するエラーが報告されます

Corrective Action  : Need manual intervention to replicate configuration. Check EMS log and follow the corrective action.

Failed Row : Table Name: iscsi, Operation: get, Fields: SVM_DEV_ECK_LAB iqn.1992-08.com.netapp:sn.00bde00000b911eda00000a000ef000:vs.102 SVM_DEV_ECK_LAB - up 0 20 15 4 128 131400 - - - - 0bf0cf14-00b0-00ed-b300-00a000ef5a0e 00bde00-00b0-00ed-a020-00a000ef0000 -
                         Failed Reason : Unrecoverable error during configuration replication, requires manual intervention. Error: You do not have a valid license for "iSCSI". Reason: Package "iSCSI" is not licensed in the cluster.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.