メインコンテンツへスキップ

fcvi.qlgc.qpErr: FC-VI アダプタ: ポート x の FCVI ドライバが、Brocade スイッチの故障した SFP が原因でストレージ上で QP エラーを受信しました

Views:
29
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • ONTAP 9
  • ファブリック接続MetroCluster
  • Brocadeスイッチ

問題

  • NetAppノードのEMSログで次のエラーが報告されます

Sat Jan 11 18:50:31 +0100 [clusterA-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: InterconnectAdapterOfflineAlert[500a0981XXXXXXXX].

fcvi.qlgc.qpErr: FC-VI adapter: FCVI driver on port X received QP Error. QP name = Control, QP
index = 0x1, VI state = Error(state code = 0x3), sub-error = Message ID error(OOD)(error code = 0x6). Remote node's system id =x. This error has occured X times.

7/25/2023 02:22:09  NodeA_1 ERROR fcvi.qlgc.ioErr: FC-VI adapter: FCVI driver on port 5a received IO error. Status = FW detected response error(status code = 0x121), FCVI opcode = Write Request(0x1), QP name = WAFL, QP index = 2, Remote node's system id = xxxxxxx.

  • Brocadeスイッチは、portterrshowコマンドの出力で影響を受けるポートにエラーを報告します。

porterrshow     :
      frames    enc   crc   crc   too   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
    tx    rx    in   err   g_eof  shrt   out   c3   fail   sync   sig          tx   rx   err   err
  2:   2.1g   1.1g   0    0    0    0    0    64    2    0    2    0    0    0    0    0    0
  3:   2.3g 352.2m   0    4   4    0    0    8.7k  28.7k  1   28.6k  0    0    8.7k  5   1.2k  0

  • Brocadeスイッチは、sfpshowコマンドの出力で影響を受けるポートのTX電力が低いことを報告します。

sfpshow -all :
=============
Port  3:
=============
Current:     10.450  mAmps
Voltage:     3306.4  mVolts
RX Power:    -2.7    dBm (534.3uW)
TX Power:    -6.3    dBm (234.6 uW)

  • Frame du detected エラーが errdump で表示される。

2024/08/21-20:37:59, [AN-1014], 922860, FID 128, INFO, switcha, Frame du detected, tx port 4 rx port 0, sid 7xxx0, did 7xxxx0, timestamp 2024-08-21 20:37:59 .
2024/08/21-20:40:10, [AN-1014], 922950, FID 128, INFO, switcha, Frame du detected, tx port 4 rx port 0, sid 7xxx0, did 7xxxx0, timestamp 2024-08-21 20:40:10 .

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.