メインコンテンツへスキップ

ONTAP Selectアグリゲート状態不明

Views:
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
ontapselect
Last Updated:

環境

ONTAP Select

問題

  • ステータスが不明なアグリゲートが1つ以上あります
    Aggregate Size Available Used% State #Vols Nodes RAID Status --------- -------- --------- ----- ------- ------ ---------------- ------------ Aggr_01 - - - unknown - Node_01 -
  • コマンド::*> disk show  は障害ディスクを検出します
    RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- failed 0b.8 0b - - SA:A 0 SSD N/A 8650745/17716727296 8650751/17716740088 failed 0d.21 0d - - SA:A 1 SSD N/A 8650745/17716727296 8650751/17716740088
  • すべてのインターフェースが稼働中です
  • EMSログには以下が表示されます:
    disk_server_0: shm.threshold.checksumErrors:error]: shm: Disk ID has exceeded the threshold for checksum errors on the same block; the system will fail the disk. config_thread: raid.config.filesystem.disk.failed:error]: File system Disk /Aggregate/plex0/rg0/0b.8 S/N ... UID ... failed. config_thread: raid.vol.failed:notice]: Aggregate Aggregate: Failed due to multi-disk error. config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED raid_disk_thread: raid.disk.unload.done:info]: Unload of Disk 0b.8 S/N ... UID ... has completed successfully dmgr_thread: raid.notify.on.failure:debug]: Received SDM_NOTIFY_ON_FAILURE for disk uid ..., originating sysid ..., with failure reason 1 (failed). config_thread: ha.panicInfoSent:notice]: Node successfully sent a panic information message to its HA partner. config_thread: sk.panic:alert]: Panic String: System encountered a forced panic condition in SK process config_thread

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.