メインコンテンツまでスキップ

ONTAP Select :古い SANtricity OS が原因で vnvram DMA .long.wait が記録されます

Views:
50
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
cloud
Last Updated:

環境

  • NetApp ONTAP の選択
  • VMware
  • NetApp Eシリーズ
  • NetApp SANtricity 11.70R3 (以前)

問題

---- EMS_LOG ----
wafl_exempt00: vnvram.dma.long.wait:alert]: vNVRAM flush taking over 10 second

  • VMware のログには、バックエンドストレージまたは iSCSI トランスポート問題が記録されています。

---- vmkwarning.log ----2021-05-10T18:16:27.205Z cpu11:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:699: vmhba64:CH:1 T:0 CN:0: iSCSI connection is being marked "OFFLINE" (Event:6)2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:700: Sess [ISID: 00023d000003 TARGET: iqn.1992-08.com.netapp:2804.600a098000db10c2000000005b0e507e TPGT: 1 TSIH: 0]2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:701: Conn [CID: 0 L: xxx.xxx.xx.x:34428 R: 192.168.34.7:3260]2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:880: vmhba64:CH:1 T:0 CN:0: iSCSI connection is being marked "ONLINE"2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:881: Sess [ISID: 00023d000003 TARGET: iqn.1992-08.com.netapp:2804.600a098000db10c2000000005b0e507e TPGT: 1 TSIH: 0]2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:882: Conn [CID: 0 L: xxx.xxx.xx.x:10121 R: 192.168.34.7:3260]2021-05-16T18:15:33.335Z cpu11:2101876)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-16T18:15:33.336Z cpu0:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-26T19:59:23.954Z cpu6:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-26T19:59:23.955Z cpu12:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-27T00:29:25.272Z cpu12:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-27T00:29:25.273Z cpu0:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-28T14:00:34.010Z cpu1:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-28T14:00:34.011Z cpu10:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-30T02:05:40.894Z cpu33:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-30T02:05:40.895Z cpu11:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-31T07:15:33.656Z cpu38:2101876)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-31T07:15:33.657Z cpu3:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-08T17:30:32.816Z cpu33:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-08T17:30:32.816Z cpu16:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-10T10:16:11.546Z cpu7:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-10T10:16:11.546Z cpu3:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-14T18:16:36.032Z cpu32:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-14T18:16:36.033Z cpu18:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.