メインコンテンツへスキップ

複数のクライアントホストが、それぞれのブロックサービスからの読み取りに失敗したために読み取りエラーを報告する

Views:
11
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

環境

  • Elementソフトウェア
  • クライアントホストからI/Oエラーが報告される
  • xNoBServicesForBinRead sf-slice.error ログで確認されます。

問題

  • 複数のホストから読み取りエラーが報告される

Jan 6 01:07:00 xxxxxxxx kernel: sd 5:0:0:0: [sde] tag#111 timing out command, waited 180s
Jan 6 01:07:00 xxxxxxxx kernel: sd 5:0:0:0: [sde] tag#111 FAILED Result: hostbyte=DID_OK driverbyte=DRIVER_OK cmd_age=180s
Jan 6 01:07:00 xxxxxxxx kernel: sd 5:0:0:0: [sde] tag#111 CDB: Read(10) 28 00 00 0a a8 08 00 07 f8 00
Jan 6 01:07:00 xxxxxxxx kernel: blk_update_request: I/O error, dev sde, sector 698376 op 0x0:(READ) flags 0x0 phys_seg 255 prio class 0

WARNING: Read Failed. group:3 disk:0 AU:85 offset:4096 size:1044480
path:/dev/asmdevices/aaa
 incarnation:0xf0f0c1d2 synchronous result:'I/O error' ioreason:13331 why:52
     subsys:System krq:0x7fa7582d6c60 bufp:0x7fa75661d000 osderr1:0x69c0 osderr2:0x0
     IO elapsed time: 0 usec Time waited on I/O: 0 usec

Dec 16 01:37:11 yyyyyyyy kernel: blk_update_request: I/O error, dev sdw, sector 1841152 op 0x0:(READ) flags 0x0 phys_seg 512 prio class 0
Dec 16 01:38:20 yyyyyyyy kernel: blk_update_request: I/O error, dev sdw, sector 227344 op 0x0:(READ) flags 0x0 phys_seg 510 prio class 0
Dec 16 01:40:10 yyyyyyyy kernel: blk_update_request: I/O error, dev sdw, sector 8308736 op 0x0:(READ) flags 0x4000 phys_seg 512 prio class 0

Dec 25 01:32:06 xxxxxxxx kernel: sd 22:0:0:0: [sdw] tag#88 CDB: Read(10) 28 00 00 97 48 00 00 10 00 00
Dec 25 01:32:06 zzzzzzzz kernel: blk_update_request: I/O error, dev sdw, sector 9914368 op 0x0:(READ) flags 0x4000 phys_seg 512 prio class 0
Dec 25 01:32:06 zzzzzzzz kernel: sd 22:0:0:0: [sdw] tag#80 timing out command, waited 180s
Dec 25 01:32:06 zzzzzzzz kernel: sd 22:0:0:0: [sdw] tag#80 FAILED Result: hostbyte=DID_OK driverbyte=DRIVER_OK cmd_age=180s

  •  tsEvent : クラスタイベントでreturn code :17 を監視

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.