bond10G問題 が原因のincorrectBondPortCountアラートとvolumesDegradedアラート
環境
- NetApp SolidFire
- NetApp HCI ストレージノード
問題
- ActiveIQから検出されるアラートは次のとおりです。
volumesDegraded Local replication and synchronization of the following volumes is in progress. Progress of the synchronization can be seen in the Running Tasks window. [xx] Replication and syncing finished for volumes: [xx, xx, xx, xx, ....]
mtuCheckFailure Failed to send messages between nodes using the maximum configured MTU (9000). Messages between the following nodes failed: { 1 -> 12, 5 -> 12, 8 -> 12, 11 -> 12, 12 -> 1, 12 -> 11, 12 -> 5, 12 -> 8 }. Incorrect MTU settings can prevent garbage collection from running and cause performance problems.
incorrectBondPortCount Incorrect bond port counts detected on the sipi interfaces of nodes: {12}
nodeOffline The SolidFire Application cannot communicate with Storage node having node ID 12.
eth0
とeth1
の両方が、からリンクのダウンとアップを頻繁に検出しますkernel.log