メインコンテンツまでスキップ

NodeOffline アラートが発生すると、イニシエータホストで I/O エラーが発生します

Views:
229
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

に適用されます

Element ソフトウェア

問題

  • ノード障害が原因で nodeOffline アラートが発生したあと、イニシエータホストで I/O エラーが発生します。
  • iscsid.conf ホストでは、次のようになります。

node.session.timeo.replacement_timeout = 120
node.conn[0].timeo.login_timeout = 15
node.conn[0].timeo.logout_timeout = 15
node.conn[0].timeo.noop_out_timeout = 5
node.session.err_timeo.abort_timeout = 15
node.session.err_timeo.lu_reset_timeout = 20

  • ホストのログに、 iSCSI ping タイムアウトが発生してから 120 秒経過する前に I/O エラーが報告されています。

例:

May 14 22:10:26 initiatorhost kernel: connection9:0: ping timeout of 5 secs expired, recv timeout 5, last rx 15465027362, last ping 15465032364, now 15465037377
May 14 22:10:26 initiatorhost kernel: connection9:0: detected conn error (1022)
May 14 22:10:26 initiatorhost iscsid: Kernel reported iSCSI connection 9:0 error (1022 - Invalid or unknown error code) state (3)
May 14 22:10:31 initiatorhost kernel: session9: session recovery timed out after 120 secs
May 14 22:10:41 initiatorhost kernel: sd 10:0:0:0: rejecting I/O to offline device
May 14 22:10:41 initiatorhost kernel: sd 10:0:0:0: [sdi] killing request
May 14 22:10:41 initiatorhost kernel: sd 10:0:0:0: rejecting I/O to offline device
May 14 22:10:41 initiatorhost kernel: sd 10:0:0:0: [sdi] FAILED Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
May 14 22:10:41 initiatorhost kernel: sd 10:0:0:0: [sdi] CDB: Write(10) 2a 00 1d 35 69 09 00 00 05 00
May 14 22:10:41 initiatorhost kernel: blk_update_request: I/O error, dev sdi, sector 490039561

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.