メインコンテンツまでスキップ

FOS v8.2.3bへのアップグレード後、Brocadeスイッチが定期的に自動リブートします

Views:
9
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2009489335</a>
Last Updated:

環境

  • Brocadeスイッチ
  • Brocade FOS v8.2.3b

問題

  • Brocadeスイッチは、FOSをv8.2.3bにアップグレードしたあとに定期的にリブートし、 errdump 次のエラーメッセージがログに記録されます。
 
2023/02/20-16:10:00, [HAM-1004], 346, CHASSIS, INFO, Brocade6510, Processor rebooted - Software Fault:Kernel Panic.
2023/02/20-16:47:59, [HAM-1004], 349, CHASSIS, INFO, Brocade6510, Processor rebooted - Reset.
2023/02/20-17:07:44, [HAM-1004], 364, CHASSIS, INFO, Brocade6510, Processor rebooted - Reboot @ 02202023-170635.
2023/02/20-17:32:57, [HAM-1007], 378, FFDC | CHASSIS, CRITICAL, Brocade6510, Need to reboot the system for recovery, reason: Software Bootup Failure:Bringup timed out.
2023/02/20-17:33:27, [HAM-1008], 382, FFDC | CHASSIS, CRITICAL, Brocade6510, Rebooting the system for recovery - auto-reboot is enabled.
2023/02/20-17:34:25, [HAM-1004], 386, CHASSIS, INFO, Brocade6510, Processor rebooted - Software Bootup Failure:Bringup timed out.
2023/02/20-17:59:35, [HAM-1007], 400, FFDC | CHASSIS, CRITICAL, Brocade6510, Need to reboot the system for recovery, reason: Software Bootup Failure:Bringup timed out.
2023/02/20-18:00:05, [HAM-1008], 404, FFDC | CHASSIS, CRITICAL, Brocade6510, Rebooting the system for recovery - auto-reboot is enabled.
2023/02/20-18:01:02, [HAM-1004], 408, CHASSIS, INFO, Brocade6510, Processor rebooted - Software Bootup Failure:Bringup timed out.
  • スイッチは、 RAS ログに記録されている以下のエラーメッセージに従ってfaultyに設定されています。

2023/02/20-16:16:16,[EM-1134], 509, FFDC | CHASSIS, ERROR, Brocade6510, Switch set to faulty,rc=20045.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.