Brocade スイッチ X6-8 が "HQx_BROx6_07, Processor rebooted - Reset." エラーでリブートされました
環境
- Brocade スイッチ X6-8
- FOS v8.2.1c
問題
Brocade スイッチ X6-8 が
errdump
再起動し、ログに次のエラーが記録される。2022/04/25-17:07:21, [EM-1033], 189, SLOT 2 | CHASSIS, ERROR, HQx_BROx6_07, CP in WWN 1 set to faulty because CP ERROR asserted.
2022/04/25-17:07:21, [EM-1047], 190, SLOT 2 | CHASSIS, INFO, HQx_BROx6_07, CP in slot 1 not faulty, CP ERROR deasserted.
2022/04/25-17:07:21, [FV-1002], 191, SLOT 2 | FID 128, INFO, HQx_BROx6_07, Flow Vision Config Replay Completed Successfully.
2022/04/25-17:07:27, [MAPS-1201], 192, SLOT 2 | FID 128, INFO, HQx_BROx6_07, MAPS has started monitoring with DCBJ_policy policy.
cifications.
_SYNC,0] has contributed to switch status MARGINAL.
2022/04/25-17:07:33, [MAPS-1020], 195, SLOT 2 | FID 128, WARNING, HQx_BROx6_07, Switch wide status has changed from HEALTHY to MARGINAL.
2022/04/25-17:08:25, [HAM-1004], 196, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, Processor rebooted - Reset.
2022/04/25-17:08:25, [SRM-1002], 197, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, raslog keep alive period has been changed to 1.
2022/04/25-17:08:25, [FV-1001], 198, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, Flow Vision daemon initialized.
2022/04/25-17:08:33, [ESM-1002], 199, SLOT 1 | FID 128, INFO, HQx_BROx6_07, ESMd initialization done for service fcsw:0.
2022/04/25-17:08:46, [FSSM-1002], 200, SLOT 2 | CHASSIS, INFO, HQx_BROx6_07, HA State is in sync.
2022/04/25-17:08:46, [FSSM-1002], 201, SLOT 1 | CHASSIS, INFO, HQx_BROx6_07, HA State is in sync.
2022/04/25-17:09:01, [MAPS-1020], 202, SLOT 2 | FID 128, WARNING, HQx_BROx6_07, Switch wide status has changed from MARGINAL to HEALTHY.