メインコンテンツまでスキップ

Brocadeスイッチポートがフラップしてもメディアエラーは報告されません

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2009528814</a>
Last Updated:

環境

Brocadeスイッチ

問題

  • Brocadeスイッチポートがフラップしても、でメディアエラーが報告されません porterrshow
  • Switchshow ポートがオンラインであることを報告します。
 
/fabos/bin/switchshow :
switchName: BROCADEXX
switchType: 166.0
switchState: Online
switchMode: Native
Index Slot Port Address Media  Speed     State   Proto
============================================================
240  12  16  67f040  id   N16  Online    FC  F-Port  x1:00:00:24:ff:1d:xx:xy
 
 
 
/fabos/cliexec/porterrshow :
frames     enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy   c3timeout   pcs    uncor
tx    rx    in   err   g_eof  shrt   long   eof   out   c3    fail   sync   sig            tx    rx    err   err
240:   2.5k   2.5k   0    0    0    0    0    0    0    0    5    0    5    0    0    0    0    0    0
 
 
  • Fabriclog に、ポートフラッピングが一度だけ発生したことを示します。
04:14:47.513170 SCN Port Offline;rsn=0x4,g=0x20        A2,P0  A2,P0  240   NA
04:14:47.513177 *Removing all nodes from port         A2,P0  A2,P0  240   NA
04:14:47.000670 SCN LR_PORT(0);g=0x5ea            A2,P0  A2,P0  240   NA
04:14:47.065831 SCN Port Online; g=0x5ea,isolated=0      A2,P0  A2,P1  240   NA
04:14:47.065910 Port Elp engaged               A2,P1  A2,P0  240   NA
04:14:47.065920 *Removing all nodes from port         A2,P0  A2,P0  240   NA
04:14:47.066147 SCN Port F_PORT                A2,P1  A2,P0  240   NA
 
 
  • SFPのtx電力とrx電力が次の推奨範囲内です: sfpshow 
=============
Slot 12/Port 16:
=============
 
RX Power:   -2.8   dBm (528.3uW)
TX Power:   -1.7   dBm (677.0 uW)
 
  • Portshow Lr-in が次の値より大きい Ols_out

Lr_in:        1     Ols_in:     0
Lr_out:       0     Ols_out:    0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.