メインコンテンツまでスキップ

Cisco N9336C-FX2クラスタスイッチに対してSwitchTemperatureWarn_Alertが報告される

Views:
9
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009517620</a>
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • Cisco N9336C-FX2クラスタスイッチ
  • FAS / AFFシステム

問題

  • Ciscoクラスタスイッチのバックモジュールのイベントログで、次のアラートが生成されます。

[Node-01: mgwd: callhome.hm.alert.minor:error]: Call home for Health Monitor process cshm: SwitchTemperatureWarn_Alert[Cisco-sw1(FDOXXXXXXVM)/module-1 BACK].

  • 背面温度センサーは、スイッチの正常なステータスを報告します。

Cisco-sw1# show environment

Temperature:
--------------------------------------------------------------------
Module   Sensor     MajorThresh   MinorThres   CurTemp    Status
            (Celsius)    (Celsius)   (Celsius)
--------------------------------------------------------------------
1     FRONT       80        70      36      Ok
1     BACK       70        42      37     Ok
1     CPU        90        80      47      Ok
1     Heavenly     110        90      58      Ok

  • 温度アラームは、スイッチ側からレポートされ、リカバリされます。

Cisco-sw1%$ VDC-1 %$ %PLATFORM-2-MOD_TEMPMINALRM: Module-1 reported minor temperature alarm. Sensor=2 Temperature=43 MinThreshold=42
Cisco-sw1%$ VDC-1 %$ %PLATFORM-2-MOD_TEMPOK: Module-1 recovered from minor temperature alarm. Sensor=2 Temperature=41 MinThreshold=42

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.