メインコンテンツまでスキップ

vm.dev.diskSlowIO が原因で、 ONTAP Select インスタンスのパフォーマンスが低下しています

Views:
33
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
perf
Last Updated:

環境

  • ONTAP 9
  • ONTAP Select
  • VMware

問題

  • CIFS クライアントからのアクセスが遅い。

NODE-01 ERROR Nblade.CifsOperationTimedOut: Detected a timed out CIFS operation. SMB command for this operation: SMB2_COM_SESSION_SETUP, Number of times this command was suspended: 1, Number of times this command was restarted: 0, Last CSM error during this operation: CSM_OK, Remote blade UUID: 00000000000000000000000000000000, Is QoS enabled: QoS_disabled, Last SpinNp error during this operation: SPINNP_NO_FO_ERROR, Client IP address: 10.89.243.174, Local IP address: 10.84.6.38, Target Vserver ID: 2, Target disk's DSID: 0

  • ONTAP の EMS ログには、その他のエラーが記録されています。

NODE-01 ALERT sk.panic: Panic String: spin lock 0xffffffff81217148 (smp rendezvous) held by 0xfffff80188858000 (CCMA-Worker) too long. VM may have been paused. Check VM host logs for an error. in SK process CCMA-Worker on release 9.3P11 (C)

NODE-01 EMERGENCY vm.host.error: The VM is paused possibly due to a full datastore or connectivity to the datastore might have been lost. Check the hypervisor logs for errors, and then perform any necessary corrective actions as soon as possible.

NODE-01 ALERT vnvram.dma.long.wait: vNVRAM flush taking over 10 seconds.

NODE-01 ERROR vm.dev.diskSlowIO: The read request on disk scsi3:0:0 took 25 seconds (data size 131072 bytes, threshold 20 seconds).

NODE-01 ERROR vm.dev.diskSlowIO: The write request on disk scsi0:0:0 took 47 seconds (data size 32768 bytes, threshold 20 seconds).

  • VMware Hostd のログに次のエラーが記録されています。

2021-06-05T20:12:00.008Z warning hostd[2486798] [Originator@6876 sub=Statssvc] Calculated read I/O size 583759 for scsi0:0 is out of range -- 583759,prevBytes = 10772597760 curBytes = 10817547264 prevCommands = 27094curCommands = 27171

  • VMware Vmkernel のログには以下のエラーが記録されています。

2021-06-05T20:12:11.584Z cpu2:2098072)ScsiDeviceIO: 3469: Cmd(0x459a79a2a380) 0x1a, CmdSN 0xd3d8c from world 0 to dev "naa.64cd98f05c7681002456ea353f4d93fb" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x50x240x0.

2021-06-05T20:13:22.054Z cpu20:2098072)ScsiDeviceIO: 3469: Cmd(0x459ab3313800) 0x4d, CmdSN 0x3f11 from world 2099775 to dev "naa.64cd98f05c768100248a2fefdc4606f1" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x50x200x0.

2021-06-05T20:16:47.745Z cpu36:2098022)DVFilter: 6053: Checking disconnected filters for timeouts

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.