環境

  • ONTAP 9
  • クラスタ スイッチ ヘルス モニタ(CSHM)AutoSupportメッセージ

問題

  • スイッチのサブシステムヘルスが低下します。

cluster1::> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor ok
Switch-Health    degraded
CIFS-NDO      ok
Motherboard     ok
IO         ok
MetroCluster    ok
MetroCluster_Node ok
FHM-Switch     ok
FHM-Bridge     ok
SAS-connect_Cluster ok

  • EMSは、次のいずれかの健全性アラートを1つ以上報告します。
    [Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1(FOCXXXXXXXX) raised by monitor ethernet-switch
    [Node_01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConfig_Alert , Alerting Resource = node_01 raised by monitor cluster-switch
    [Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchCommunityString_Alert , Alerting Resource = SW1 raised by monitor cluster-switch
    [Node-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchLinkDiscoveryProtocol_Alert , Alerting Resource = Switch-SW1 raised by monitor ethernet-switch
  • system health alert showの出力も同様に、次のいずれかを1つ以上表示します。

        Node: node-01
      Alert ID: SwitchUnreachable_Alert
      Resource: sw1
   Probable Cause: The ethernet switch's IP address is not reachable from
           the local node.
   Possible Effect: Monitoring of the switch and log collection will not
           function.
Corrective Actions: Ensure that the IP address is reachable or specify the
           correct reachable IP address.

        Node: node-01
      Alert ID: ClusterSwitchConfig_Alert
      Resource: node-01
   Probable Cause: One or more nodes are not connected to both cluster
           switches.
   Possible Effect: If one cluster switch fails, "node0-1" might lose
           access to the cluster.
Corrective Actions: Ensure the switch "sw1" is connected
           to the node "node-01".

        Node: node-01
      Alert ID: SwitchCommunityString_Alert
      Resource: sw1
   Probable Cause: Cluster switch "sw1" with IP address
           "123.123.123.123" is not reachable via SNMP. Incorrect
                SNMP community string might be configured on the
                cluster switch.
   Possible Effect: Cluster switch communication problems and
           accessibility issues.
Corrective Actions: Check the SNMP community string on the cluster switch
           to verify the expected community string is configured.
                Use the "system cluster-switch show -snmp-config"
                command to view the expected community string.

 Node: Node-103B
      Alert ID: SwitchLinkDiscoveryProtocol_Alert
      Resource: Switch-SW2
      Severity: Minor
   Indication Time: Mon Aug 04 18:01:22 2025
      Suppress: false
 Acknowledge: false
   Probable Cause: The ethernet switch is using an unsupported link
           discovery protocol.
  Possible Effect: The change of the link discovery protocol on the
           switch is not supported. The connected device will not
           appear in link layer discovery commands.
 Corrective Actions: Revert the discovery protocol change on the switch.

  • アラートのスイッチ名とIPアドレスは、いずれのクラスタスイッチにも属しておらず、またはスイッチレスクラスタの場合に報告されます。
  • Command system switch ethernet show は空白または不明であるか、IP address not reachableを持つスイッチを報告します。
  • ヘルスアラートを削除しても問題は解決しません。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.