ピアキーの不一致が原因で LACP ポートが停止しています

Views:
63
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network<a>LACP</a>
Last Updated:

環境

  • ONTAP 9
  • LACP ifgrp

問題

ONTAP が LACP ピアと異なるキーを受信したため、 ifgrp 内で 1 つ以上のインターフェイスがアクティブになっていません。

次の例では、「 ifconfig -v」を使用して以下の情報を表示しています。

  • LACP ピアが 2 つの異なる( keys0036 と 0037 )を送信している
  • の ifgrp にインターフェイスを 1 つだけ残します ACTIVE state

::> system node run -node <node> -command ifconfig -v

a0a: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 9000
options=6407bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,LRO,VLAN_HWTSO>
ether 02:a0:98:11:22:33
media: Ethernet autoselect
status: active
groups: lagg
laggproto lacp lagghash l3
lagg options:
flags=11<USE_FLOWID,LACP_STRICT>
flowid_shift: 16
lagg statistics:
active ports: 1 <-- Only one out of the two configured port is currently active in the ifgrp
flapping: 0
lag id: [(8000,02-A0-98-11-22-33,0032,0000,0000),
(8000,AA-BB-CC-DD-EE-FF,0037,0000,0000)]
laggport: e0d flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> state=3d<ACTIVITY,AGGREGATION,SYNC,COLLECTING,DISTRIBUTING>
[(8000,02-A0-98-11-22-33,0032,8000,0006),     <-- ontap
(8000,AA-BB-CC-DD-EE-FF,0037,8000,00B9)]      <-- peer
input/output LACPDUs: 460 / 14099
laggport: e0c flags=18<COLLECTING,DISTRIBUTING> state=3d<ACTIVITY,AGGREGATION,SYNC,COLLECTING,DISTRIBUTING>
[(8000,02-A0-98-11-22-33,0032,8000,0007),      <-- ontap
(8000,AA-BB-CC-DD-EE-FF,0036,8000,043A)]      <-- peer
input/output LACPDUs: 460 / 14099

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.