メインコンテンツまでスキップ

AFF A200 / FAS26XXで、テイクオーバー中にシェルフの温度が173 Cに達していないと報告されます

Views:
43
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009503271.</a>
Specialty:
hw
Last Updated:

環境

  • FAS2650
  • FAS2620
  • AFF A200

問題

  • 一方のノードが予期せず停止すると、HAペアの稼働しているノードから温度問題 が報告されます。
  • EMSメッセージ:

[cluster-01: dsa_worker2: callhome.shlf.overtemp:error]: Call home for SHELF OVER TEMPERATURE 173 C (343 F)
[cluster-01: dsa_worker2: ses.status.temperatureError:error]: DS224-12 (S/N SHF000000000000) shelf 0 on channel 0b temperature error for Temperature sensor 14: critical status; overtemperature failure. Current temperature: 173 C (343 F). This module is on the rear of the shelf at the top right, on shelf module B.

  • 環境出力:
Shelf temperatures by element:
[1] 29 C (84 F) (ambient)  Normal temperature range
[2] 33 C (91 F)  Normal temperature range
[3] 33 C (91 F)  Normal temperature range
[4] 29 C (84 F)  Normal temperature range
[5] 29 C (84 F)  Normal temperature range
[6] 31 C (87 F)  Normal temperature range
[7] 32 C (89 F)  Normal temperature range
[8] 31 C (87 F)  Normal temperature range
[9] 43 C (109 F)  Normal temperature range
[10] 36 C (96 F)  Normal temperature range
[11] 49 C (120 F)  Normal temperature range
[12] 35 C (95 F)  Normal temperature range
[13] 34 C (93 F)  Normal temperature range
[14] 173 C (343 F) Overtemperature failure!
[15] 31 C (87 F)  Normal temperature range

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.