AFF A700 が X91148A アダプタの温度を超えるとシャットダウンする
環境
- AFF A700
- FAS 9000
- X91148A イーサネットアダプタ
- X91143A CNA アダプタ
問題
CNA カードをネットワークカードと交換した
Fri Feb 04 12:42:15 -0500 [node-01: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: IO3 CNA SW DieTmp is critical high (3280 mV).
Fri Feb 04 12:42:15 -0500 [node-01: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: IO3 CNA ASIC1 DieTmp is critical high (1760 mV).
Fri Feb 04 12:42:15 -0500 [node-01: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: IO3 CNA ASIC2 DieTmp is critical high (960 mV).
Fri Feb 04 12:43:00 -0500 [node-01: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
Fri Feb 04 12:43:15 -0500 [node-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
Fri Feb 04 12:43:18 -0500 [node-01: cf_main: cf.fsm.takeover.nfo:info]: Failover monitor: takeover attempted after "storage failover takeover" command.
Fri Feb 04 12:45:15 -0500 [node-01: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Temp on I/O Slot3 is critical high. System will be shutdown in 2 minutes
Fri Feb 04 12:47:18 -0500 [node-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)