環境

  • FAS2720 / FAS2750
  • ONTAP 9

問題

  • 障害LEDは、故障したFlash Cacheを交換した後でも点灯したままです。
  • "NVMe device failed"イベントは交換後も残ります。

  • 次のコマンドを実行してもエラーイベントをクリアできません。

 例:

         ::> system controller service-event delete -node node-1 -event-id 1

::> system controller service-event show

 Node        ID  Event Location            Event Description
 ---------------- --- ----------------------------------  ----------------------
      node-01  1 Device in M.2 PCIe slot 1 in Controller A  NVMe device failed

  • Fault LEDは、Baseboard Management Controller(BMC)の「system fru led set off」コマンドでクリアできません。

例:

BMC> priv set diag
BMC*> system fru led set 15 off

========
FRU LEDs status
======================
<snip>
FRU LED ID 14 = BMC DIMM Slot 2 Attention LED
FRU LED ID 15 = BMC NVMEM 1 Attention LED
FRU LED ID 16 = BMC BOOT DISK Attention LED
<snip>
FRU LED ID 14 is off
FRU LED ID 15 is on 
FRU LED ID 16 is off

  •  Flash Cache状態はOksysconfig-aに表示されます。

slot 1: Flash Cache NVMe
Serial Number: S2UWNX0HCXXXXX5
Part Number: 110-00466
Hardware Revision: A0
Firmware Version: NA00
Model Name: X3311A
Capacity: 1024 GB
State: ok

  • BMC reboot では問題を解決できません。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.