「Errors Count from cluster port seen on Cluster switch」というエラーが表示されます
環境
- FAS8200
- CN1610
問題
- 「Errors Count from cluster port seen on Cluster switch」というエラー数が原因で、パフォーマンス問題 が生成されます
Switch Name: Clus-switch1
Switch Type: cluster-network
Interface name: Slot: 0 Port: 4 10G - Level
In Error Count: 195241906
In Ucast Packet Count: 1898860469
In Non-Ucast Packet Count: 417863
In Error %: 2
In Error % (Conv int): 235
In Error % (decimal): 2.353582422295592 << -----------
Out Error Count: 0
Out Ucast Packet Count: 714261296
Out Non-Ucast Packet Count: 5347101
Out Error %: 0
Out Error % (Conv Int): 0
Out Error % (decimal): 0
In warning Count: 2
Out warning Count: 0
- クラスタLIFがEMSログでフラッピングとして報告します
[Node01: vifmgr: vifmgr.port.monitor.failed:error]: The "link_flapping" health check for port e0b (node Node01) has failed. The port is operating in a degraded state.