メインコンテンツまでスキップ

LUN のマッピングまたはマッピング解除コマンドがタイムアウトエラーで失敗する

Views:
27
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

環境

  • ONTAP 9.1P20
  • FCP
  • 論理ユニット( LUN )

問題

  • lun map または lun unmap コマンドがタイムアウトエラーで失敗する:
::> lun map -vserver SVMFC -path /vol/volfc/lun1 -igroup XEN01 46
Error: command failed: Timeout: Operation "vdiskAction_lunMap_iterator::modify_imp()" took longer than 120 seconds to complete

::> lun unmap -vserver SVMFC -path /vol/volfc/lun2 XEN01
Error: command failed: Timeout: Operation "vdiskAction_lunUnmap_iterator::modify_imp()" took longer than 120 seconds to complete

  • SCSIBLADE VSERVER OPERATION TIMEOUT エラーは次の場所に表示 EMS.logされます。
 
3/17/2021 16:20:24  node01    ERROR     callhome.sblade.vs.op.tt: Call home for SCSIBLADE VSERVER OPERATION TIMEOUT
3/17/2021 16:20:24  node02    ERROR     callhome.sblade.vs.op.tt: Call home for SCSIBLADE VSERVER OPERATION TIMEOUT
3/17/2021 16:20:24  node03    ERROR     callhome.sblade.vs.op.tt: Call home for SCSIBLADE VSERVER OPERATION TIMEOUT
3/17/2021 16:20:24  node03    EMERGENCY   scsiblade.vserver.op.timeout: A Vserver internal operation (0x000000d9) has timed out. Vserver SVMFC might not be available to process additional SAN management commands and events.
3/17/2021 16:20:24  node04    ERROR     callhome.sblade.vs.op.tt: Call home for SCSIBLADE VSERVER OPERATION TIMEOUT
3/17/2021 16:20:24  node04    EMERGENCY   scsiblade.vserver.op.timeout: A Vserver internal operation (0x000000d9) has timed out. Vserver SVMFC might not be available to process additional SAN management commands and events.
3/17/2021 16:19:42  node02    ERROR     ctran.gc.proposal.stuck: CTRAN group f2416cc0-529f-11e3-8ede-123478563412 has attempted a prop_done probe 13 times against gm_id 106 on node UUID 820b005f-4e61-11e6-85d6-bba057bd2059 for txn 3373652295.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?