SPファームウェアイメージがリセットされたため、ノードが環境理由シャットダウン(温度が重要)でリブートします

Views:
5
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009185913</a>
Specialty:
hw
Last Updated:

環境

  • FAS
  • AFF

問題

  • 次のイベントでノードが停止します。

Wed May 25 00:48:24 UTC [pv35p45im-filerm45003: env_mgr: monitor.temp.unreadable:info]: The controller temperature (CPU1 Temp Margin) is not readable.
Wed May 25 00:48:24 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVCCP CPU0 in the controller module is not readable.
Wed May 25 00:51:16 UTC [pv35p45im-filerm45003: spsm_listener: sp.heartbeat.stopped:warning]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.chassisFan.stop:alert]: Chassis fan contains at least one stopped fan: SysFan3 F1 (failed)
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.temp.unreadable:info]: The controller temperature (In Flow Temp) is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.chassisTemperature.state.unknown:warning]: Chassis temperature state is unknown: Multiple Temp sensors are unreadable. System will be shutdown in 2 minutes.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PCH Hot in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P5V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P3.3V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P1.8V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor P0.9V STBY in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVDDQ DDR3 AB in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.power.unreadable:info]: A power sensor PVTT DDR3 AB in the controller module is not readable.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Multiple chassis fans have failed.
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: env_mgr: callhome.fans.failed:EMERGENCY]: Call home for MULTIPLE FAN FAILURE
Wed May 25 00:51:19 UTC [pv35p45im-filerm45003: statd: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)

  • ノードがリブートし、ギブバックステータスが待機状態になります。
  • リブート中のサービスプロセッサのステータスがUNKNOWNと表示される
    Node>sysconfig -a

Service Processor
                    Status: Unknown
                    IPMI: unknown
                  PKT: unknown

  • SPログからSPリセットイベントを確認できませんでした。

sp>events all
SP recovered successfully after a reset from primary FW image.

  •  ノードのリブート中に、サービスプロセッサが自動でリブートされたことがわかりました。

sp>sp uptime
02:17:43 up 2:27, load average: 1.29, 1.15, 1.10

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.