メインコンテンツまでスキップ

DS224C の 2 台の電源装置ユニット( PSU )には、センサー読み取り値はありませんが、正常に機能しています

Views:
87
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

環境

  • DS224c
  • DS212
  • ONTAP 9

問題

DS224cの両方のPSUにセンサー読み取り値がありません。エラーステータスがAutoSupportから次のログとして表示されます。

環境:

Channel: 1c
   Shelf: 22
   SES device path: local access: 1c.22.99
   Module type: IOM12; monitoring is active  
   Shelf status: critical condition
   SES Configuration, shelf 22:
    logical identifier=XXXXXXXXXXXXXXX
    vendor identification=NETAPP  
    product identification=DS224-12
    product revision level=0230
   Vendor-specific information:
    Product Serial Number: XXXXXXXXXXXXXXX
   Status reads attempted: 52454055; failed: 0
   Control writes attempted: 0; failed: 0
   Shelf bays with disk devices installed:
    23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
    with error: none
   Power Supply installed element list: 1, 2; with error: none
   Power Supply information by element:
    [1] Serial number: XXXXXXXXXXXXXXX  Part number: 114-00148+C0
      Type: 7D
      Firmware version: 0111  Swaps: 0
    [2] Serial number: XXXXXXXXXXXXXXX  Part number: 114-00148+C0
      Type: 7D
      Firmware version: 0111  Swaps: 0
   Voltage Sensor installed element list: 1, 2, 3, 4; with error: none
   Shelf voltages by element:
    [1] <N/A> sensor condition <N/A>
    [2] <N/A> sensor condition <N/A>
    [3] <N/A> sensor condition <N/A>
    [4] <N/A> sensor condition <N/A>
   Current Sensor installed element list: 1, 2, 3, 4; with error: none
   Shelf currents by element:
    [1] 0 mA Normal current range
    [2] 0 mA Normal current range
    [3] 0 mA Normal current range
    [4] 0 mA Normal current range
   Cooling Unit installed element list: 1, 2, 3, 4; with error: 1, 2, 3, 4
   Cooling Units by element:
    [1] 0 RPM
    [2] 0 RPM
    [3] 0 RPM
    [4] 0 RPM
   Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11; with error: none
   Shelf temperatures by element:
    [1] 22 C (71 F) (ambient)  Normal temperature range
    [2] 23 C (73 F)  Normal temperature range
    [3] 23 C (73 F)  Normal temperature range
    [4] 23 C (73 F)  Normal temperature range
    [5] 23 C (73 F)  Normal temperature range
    [6] 23 C (73 F)  Normal temperature range
    [7] 23 C (73 F)  Normal temperature range
    [8] Unavailable
    [9] Unavailable
    [10] 29 C (84 F)  Normal temperature range
    [11] 29 C (84 F)  Normal temperature range
   Temperature thresholds by element:
    [1] High critical: 52 C (125 F); high warning: 47 C (116 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [2] High critical: 60 C (140 F); high warning: 55 C (131 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [3] High critical: 60 C (140 F); high warning: 55 C (131 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [4] High critical: 60 C (140 F); high warning: 55 C (131 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [5] High critical: 60 C (140 F); high warning: 55 C (131 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [6] High critical: 62 C (143 F); high warning: 57 C (134 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [7] High critical: 100 C (212 F); high warning: 90 C (194 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [8] High critical: 62 C (143 F); high warning: 57 C (134 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [9] High critical: 100 C (212 F); high warning: 90 C (194 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [10] High critical: 90 C (194 F); high warning: 85 C (185 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
    [11] High critical: 90 C (194 F); high warning: 85 C (185 F)
      Low critical:  0 C (32 F); low warning:  5 C (41 F)
   ES Electronics installed element list: 1, 2; with error: none
   ES Electronics reporting element: 1
   ES Electronics information by element:
    [1] Serial number: XXXXXXXXXXXXXXX  Part number: 111-02850+C2
      CPLD version: 24  Swaps: 0
    [2] Serial number: XXXXXXXXXXXXXXX  Part number: 111-02850+C2
      CPLD version: 24  Swaps: 0
   Enclosure element list: 1; with error: none;
   Enclosure information:
    [1] WWN: XXXXXXXXXXXXXXX  Shelf ID: 22
      Serial number: XXXXXXXXXXXXXXX  Part number: 116-00514+C0
      Midplane serial number: XXXXXXXXXXXXXXX  Midplane part number: 110-00541+A0

ストレージ障害:

Enclosure Status: critical
Channel: 1c
Shelf: 22
Shelf Type: DS224-12
Product Serial Number: XXXXX1111111111
Module Type: IOM12

Disk Elements:
Element Status          Status Bytes  Status Descriptions
  0 [Bay  0]: NONCRITICAL     03,00,00,00   
  1 [Bay  1]: NONCRITICAL     03,01,00,00   
  2 [Bay  2]: NONCRITICAL     03,02,00,00   
  3 [Bay  3]: NONCRITICAL     03,03,00,00   
  4 [Bay  4]: NONCRITICAL     03,04,00,00   
  5 [Bay  5]: NONCRITICAL     03,05,00,00   
  6 [Bay  6]: NONCRITICAL     03,06,00,00   
  7 [Bay  7]: NONCRITICAL     03,07,00,00   
  8 [Bay  8]: NONCRITICAL     03,08,00,00   
  9 [Bay  9]: NONCRITICAL     03,09,00,00   
 10 [Bay 10]: NONCRITICAL     03,0A,00,00   
 11 [Bay 11]: NONCRITICAL     03,0B,00,00   
 12 [Bay 12]: NONCRITICAL     03,0C,00,00   
 13 [Bay 13]: NONCRITICAL     03,0D,00,00   
 14 [Bay 14]: NONCRITICAL     03,0E,00,00   
 15 [Bay 15]: NONCRITICAL     03,0F,00,00   
 16 [Bay 16]: NONCRITICAL     03,10,00,00   
 17 [Bay 17]: NONCRITICAL     03,11,00,00   
 18 [Bay 18]: NONCRITICAL     03,12,00,00   
 19 [Bay 19]: NONCRITICAL     03,13,00,00   
 20 [Bay 20]: NONCRITICAL     03,14,00,00   
 21 [Bay 21]: NONCRITICAL     03,15,00,00   
 22 [Bay 22]: NONCRITICAL     03,16,00,00   
 23 [Bay 23]: NONCRITICAL     03,17,00,00   

Power Supplies:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,00,A0   RQSTED ON
  2: UNKNOWN       06,00,00,A0   RQSTED ON

Fans:
Element Status      Status Bytes  Status Descriptions
  1: CRITICAL      02,00,00,F0   OFF, FAIL
  2: CRITICAL      02,00,00,F0   OFF, FAIL
  3: CRITICAL      02,00,00,F0   OFF, FAIL
  4: CRITICAL      02,00,00,F0   OFF, FAIL

Temperature Sensors:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,2A,00   
  2: OK         01,00,2B,00   
  3: OK         01,00,2B,00   
  4: OK         01,00,2B,00   
  5: OK         01,00,2B,00   
  6: OK         01,00,2B,00   
  7: OK         01,00,2B,00   
  8: UNKNOWN       06,00,2E,00   
  9: UNKNOWN       06,00,2E,00   
 10: OK         01,00,31,00   
 11: OK         01,00,31,00   

Enclosure Electronics:
Element Status            Status Bytes  Status Descriptions
  1 [IOM12 A]   : OK         01,00,01,80   REPORT
  2 [IOM12 B]   : OK         01,00,00,80   

OPS Panel:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,00,00   

Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00   FAIL

Voltage Sensors:
Element Status      Status Bytes  Status Descriptions
  1: UNKNOWN       06,00,00,00   
  2: UNKNOWN       06,00,00,00   
  3: UNKNOWN       06,00,00,00   
  4: UNKNOWN       06,00,00,00   

Current Sensors:
Element Status      Status Bytes  Status Descriptions
  1: UNKNOWN       06,00,00,00   
  2: UNKNOWN       06,00,00,00   
  3: UNKNOWN       06,00,00,00   
  4: UNKNOWN       06,00,00,00   

Vendor Unique Element 83-IOM12: (SAS)
Element Status      Status Bytes  Status Descriptions
  1 [IOM12 A]  : CRITICAL      02,08,00,A4  MASTER, RESERVED, RESERVED, RESERVED
  2 [IOM12 B]   : CRITICAL      02,00,00,A4   RESERVED, RESERVED, RESERVED

Vendor Unique Element 85-IOM12: (ACP)
Element Status            Status Bytes  Status Descriptions
  1 [IOM12 A]   : OK         01,18,00,00   NO ACPP, INBACP
  2 [IOM12 B]   : OK         01,18,00,00   NO ACPP, INBACP

Input Power Monitor:
Element Status      Status Bytes  Status Descriptions
  1: UNKNOWN       06,00,00,00   
  2: UNKNOWN       06,00,00,00

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.