外部シェルフのPSUが短時間に複数回パワーオフされた場合に、SES.status.psWarningおよびpsErrorが報告されないのはなぜですか
環境
FAS2750
回答
- 外付けシェルフの1台のPSUの電源が初めてオフになった場合、次のEMSイベントが両方のノードで発生することが予想されます。
Thu Aug 18 13:28:59 +0900 [Nodename: dsa_worker2: ses.status.psWarning:error]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power warning for Power supply 1: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: ses.status.psError:alert]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power error for Power supply 1: critical status; AC Fail. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:29:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:29:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
- 同じPSUの電源が6時間以内にオフになり
ses.status.psWarning
、電源ses.status.psError
が遮断される場合は、次の手順を実行します。
Thu Aug 18 13:43:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:43:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:43:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
- これは外部シェルフに対する想定される動作であり、同じアラートリソースからの同じ警告メッセージは6時間以内に禁止されます。
追加情報
- PSUのステータスは次の方法で確認できます。
system node run -node * -command environment status
- 内蔵シェルフ(シャーシ)に搭載されているPSUで障害が発生すると、この2つのEMSイベントが停止することはありません。