内部ストレージを使用しているシステムで「 shelf_fault 」エラーが報告される
に適用されます
- ONTAP 9.5P6
- FAS2554
- サービスプロセッサ( SP ) 2.8 P1
問題
- システムは次のエラーを報告し、自動的に回復します。
例:
[?] Fri Apr 24 13:40:15 JST [node: dsa_worker1: ses.status.ACPError:alert]: DS4246 (S/N xxxxxxxxxx) shelf 0 on channel 0a ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the bottom center, on shelf module B.
[?] Fri Apr 24 13:40:24 JST [node: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[?] Fri Apr 24 13:40:24 JST [node: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
[?] Fri Apr 24 14:35:24 JST [node: dsa_worker5: ses.status.ACPInfo:info]: DS4246 (S/N xxxxxxxxxx) shelf 0 on channel 0b ACP Processor information for SAS shelf ACP processor 2: normal status.
[?] Fri Apr 24 14:35:33 JST [node: statd: monitor.shelf.fault.ok:notice]: Fault previously reported on disk storage shelf attached to channel 0a has been corrected.
[?] Fri Apr 24 14:36:00 JST [node: monitor: monitor.globalStatus.ok:notice]: The system's global status is normal.
- エラー
FAIL
STORAGE-FAULT
が発生した場合、 Alternate Control Path ( ACP )は出力のステータスになります。
例:
Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS4246
Product Serial Number: xxxxxxxxxx
Module Type: IOM6E
Vendor Unique Element 85-IOM6E: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM6E A] : OK 01,10,00,00 INBACP
2 [IOM6E B] : CRITICAL 02,10,00,40 INBACP, FAIL
- 次のレコードがから見つかり
SP-LATEST-SYSTEM-EVENT-LOG
ます。
例:
Record 1771: Fri Apr 24 05:33:18 2020 [SP.critical]: Rebooting SP due to loss of ACP comms
Record 1772: Thu Jan 1 00:00:37 1970 [IPMI.notice]: 6104 | c0 | OEM: ffff70005100 | ManufId: 150300 | SP Reset Internally