In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NVRAM ブートに関するエラーメッセージと LED が点灯するように、 AFF-A700 / FAS9000 を設定します 真のエラーなし

Views:
25
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

に適用されます

  • FAS9000

  • AFF A700  

問題

  • FAS9000 または AFF A700 で NVDIMM を交換したあとも、システムから次のようなレポートが作成されます。 

     ::> system controller service-event show -instance Node: NODE_NAME Service Event ID: 1 Location: NVDIMM 1 on PCI 6 Description: NVDIMM1:UECC detected Timestamp: Wed May 30 12:20:03 2018 Node: NODE_NAME Service Event ID:2 Location: NVDIMM 2 on PCI6 Description: NVDIMM2: UECC detected Timestamp: Wed May 30 12:20:04 2018 2 entries were displayed. 
  • ブートプロセスメッセージ、コンソールログ: 

================ Log #9 start time Tue Jun 5 14:57:30 2018 NetAppData ONTAP 9.3P4 ******************************************************* WARNING: The NVRAMDIMM1 has caused UECC in the past. Please replace it as soon as possible!!! *************************** WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! ****************************************************** 

  • SP イベント:  

Record 2434: Mon Nov 05 16:34:50.052098 2018 [IPMI.notice]: d001 | 02 |EVT: ef02ffff | NVS_Status | Deassertion Event, "Fault"

Record 141: Mon Dec 17 15:42:02.523180 2018 [IPMI.notice]: ac02 | 02 |EVT: 6f02ffff | NVS_Status | Assertion Event, "Fault" < - - - After the power off/on 

  • SP イベント: 

SP NODE_NAME> system service-event show
ID FRU Description Fault
Reason
--------------------------- -------
-----------
1 NVDIMM 1 on PCI 6
NVDIMM1: UECC detected
2 NVDIMM 2 on PCI 6
NVDIMM2: UECCdetected
Fault Lights On:
/chassis-1
PCI 6
NVDIMM 1 on PCI 6
NVDIMM 2 on PCI 6

  • EMS から UECC / NVRAM メッセージが報告されません ログ

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support